Connecting
3.3 Installing the Power Module
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
35
Dimensions and drilling patterns for the PM240 Power Modules
:LGWK
+H
LJ
K
W
:LGWK
+H
LJ
K
W
:LGWK
+H
LJ
K
W
E
D
E
D
)6$
)6%)6)
E
E
DF
F
)6*;
Figure 3-1
PM240 dimension drawing
Table 3- 1
Dimensions for the PM240 Power Modules, IP20
PM240
Power
Dimensions
Clearances
IP20
kW
Height
Width
Depth
a
b
c
top
bottom lateral
mm
inch
173
6,81
73
2,87
145
5,71
160
6,30
36,5
1,44
100
3,94
100
3,94
30*
1,18*
FSA
0,37 … 1,5
Fixing: M4 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
270
10,63
153
6,02
165
6,5
258
10,16
133
5,24
100
3,94
100
3,94
40*
1,57*
FSB
2,2 … 4
Fixing: M4 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
334
13,15
189
7,44
185
7,28
323
12,72
167
6,57
125
4,92
125
4,92
50*
1,97*
FSC
7,5 … 15
Fixing: M5 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
419
16,50
275
10,83
204
8,03
325
12,8
235
9,25
11
0,4
300
11,81
300
11,81
0
0
FSD
without
filter
18,5 … 30
Fixing: M6 screws, Torque: 6 Nm / 53 lbf.in
mm
inch
512
20,16
275
10,83
204
8,03
419
16,50
235
9,25
11
0,4
300
11,81
300
11,81
0
0
FSD with
filter,
Class A
18,5 … 30
Fixing: M6 screws, Torque: 6 Nm / 53 lbf.in