Backing up your settings
We recommend that you insert the card before switching on the inverter for the first time.
The inverter then automatically ensures that the actual parameter setting is saved both in the
inverter as well as on the card.
The following describes how you can save the inverter parameter setting on the memory
card subsequently.
Note
The data transfer can take several minutes.
If you wish to transfer the parameter setting from the inverter on to a memory card (Upload),
you have two options:
Automatic upload
Switch off the inverter power supply (or disconnect the
Control Unit from the Power Module).
Insert an empty memory card into the inverter.
Then switch the inverter power supply back on again
(or reconnect the Control Unit to the Power Module).
E:4 S C-V3N97875
s
SINAMICS
MICRO MEMORY CARD
6SL3254-0AM00-0AA0
&8
30
Transfer the setting to the
empty memory card
Afterwards, the inverter copies its parameter setting onto the memory card.
NOTICE
If the memory card is not empty and already contains a parameter setting, the inverter will
take on the parameter setting from the memory card. The previous setting in the inverter