Siemens SINAMICS CONNECT 500 Скачать руководство пользователя страница 50

Replacement parts
10.2 Replacement parts for the connectivity module

SINAMICS CONNECT 500

48

Operating Instructions, 10/2019

Содержание SINAMICS CONNECT 500

Страница 1: ...Operating Instructions SINAMICS CONNECT 500 Connectivity module 10 2019 Edition www siemens com drives ...

Страница 2: ......

Страница 3: ...tions 10 2019 Introduction 1 Safety instructions 2 Description 3 Preparation for use 4 Mounting and installation 5 Connection 6 Commissioning 7 Operation 8 Maintenance 9 Replacement parts 10 Disposal 11 Service Support A Standard topology B ...

Страница 4: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 5: ... 4 1 Transportation and storage 19 4 2 Prerequisites 19 4 3 Windows Security Center 21 4 4 Operation without antivirus software 21 5 Mounting and installation 23 5 1 Mounting and installation premounted version of the connectivity module 23 5 2 Mounting and installation connectivity module version that can be retrofitted 23 6 Connection 25 6 1 Connect the LAN cable to the IPC premounted version of...

Страница 6: ...isories via CERT 43 9 5 Replacing connectivity module components 43 9 6 Deleting the data of the connectivity module 44 9 7 Fault rectification 44 9 7 1 Restart service Drive System Connect 44 9 7 2 Setting up the connection to the converter Control Unit 45 9 7 3 Activating FTP on the Control Unit 46 10 Replacement parts 47 10 1 Spares on Web 47 10 2 Replacement parts for the connectivity module 4...

Страница 7: ...ures in these instructions 1 Handling instructions are always formatted as a numbered list Always perform the steps in the order given Lists are formatted as bulleted lists Lists on the second level are hyphenated Note The note provides you with additional information about the product itself handling the product and the relevant documentation References to other texts always refer to the beginnin...

Страница 8: ...Introduction 1 2 Naming convention SINAMICS CONNECT 500 6 Operating Instructions 10 2019 ...

Страница 9: ...when handling lithium batteries Replace used batteries in good time Additional information on replacing batteries is provided in the SIMATIC IPC127E Operating Instructions Section Replacing buffer batteries Do not throw the batteries into a fire Do not solder at the cell body of the battery Do not recharge the battery Do not open the battery Do not short circuit the battery Do not connect the batt...

Страница 10: ...s that can be destroyed by electrostatic discharge These components can be damaged or destroyed if they are not handled correctly To protect equipment against damage follow the instructions given below Only touch electronic modules if you absolutely have to work on them The body of the person concerned must have been electrostatically discharged and grounded immediately before any electronic modul...

Страница 11: ... and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segmentation are in place For additional information on industrial security measures that may be implemented please visit https www siemens com industrialsecurity https www siemens com industrialsecurity Siemens products and solutions undergo continuous development to make the...

Страница 12: ...dustrial Security Page 9 Keep yourself up to date with security advisories and bulletins published by Siemens ProductCERT https www siemens com global en home products services cert html Passwords Regularly update passwords and keys in order to increase the security level Only use strong passwords Avoid weak passwords e g password1 123456789 abcdefgh Ensure that all passwords are protected and can...

Страница 13: ...elating to the most commonly used components and installation guidelines for networked automation systems in buildings is provided here https support industry siemens com cs ww en view 84922825 Safety instructions 2 6 Security recommendations SINAMICS CONNECT 500 Operating Instructions 10 2019 11 ...

Страница 14: ...Safety instructions 2 6 Security recommendations SINAMICS CONNECT 500 12 Operating Instructions 10 2019 ...

Страница 15: ...e connectivity module Connectivity module version that can be retrofitted The connectivity module comprises the following components SIDRIVE IQ Drive System Connect Nano Industrial PC SIMATIC IPC127E Software image SCALANCE X005 LAN switch Note The connectivity module and SIDRIVE IQ are used to monitor the state condition of the converter The connectivity module cannot be used to influence the con...

Страница 16: ...ware Windows 10 7 zip Siemens Bany Scope Siemens Drive System Connect MindConnect Bridge MCB feeder Additionally available software Siemens CMS X Tools Siemens CMS X Tools Analysis Library Omicron OMSSystemSW Do not exit or deactivate any of the active services so as not to diminish the functionality of the connectivity module Description 3 1 Overview of the connectivity module SINAMICS CONNECT 50...

Страница 17: ...pport industry siemens com cs ww en view 109762673 SCALANCE X005 LAN switch Operating Instructions https support industry siemens com cs ww en view 22261701 Information about network security https support industry siemens com cs ww en view 109751848 Instructions for the connectivity module version that can be retrofitted https support industry siemens com cs ww en ps 25520 The documentation of th...

Страница 18: ...cular drive component Using the connectivity module you can transfer save and analyze operating data in SIDRIVE IQ Operating data can be displayed using SIDRIVE IQ SIDRIVE IQ provides technical data on the drive components and the results of the analysis in operation and the status for users Further it provides suggestions relating to preventive maintenance activities for example Description 3 3 S...

Страница 19: ...ion network and the external network Internet The standard topology for installation in SINAMICS GM150 is provided in the Appendix Page 53 3 5 Data security The IPC saves the converter data unencrypted until it is transferred into the Cloud The IPC transfers the data into the Cloud according to the TLS standard Transport Layer Security V1 2 encrypted via an additional firewall Windows Firewall Alw...

Страница 20: ...e connectivity module Verification of the operating system integrity Windows updates Configuration of the Windows Firewall User account control Whitelisting Whitelist Make no changes to the whitelist that go beyond commissioning and maintenance activities Personal data The connectivity module neither uses nor processes personal data Description 3 5 Data security SINAMICS CONNECT 500 18 Operating I...

Страница 21: ...ting system The local service PC must support the Microsoft Remote Desktop Protocol RDP in order to remotely access the IPC Only connect the local service PC physically and directly to the connectivity module point to point Ethernet cable Protect your local service PC against unauthorized access Under no circumstance weaken the hardening measures of the connectivity module For additional informati...

Страница 22: ...dresses You receive the following emails after Siemens customer service has created a user account User Credentials for Drive System Analyzer email with the link to the Drive System Analyzer and the appropriate login data Email with the connection key to the connectivity module Note Duration of validity The connection key for the connectivity module is valid for 7 days Initial passwords Together w...

Страница 23: ...virus software See also Chapter Operation without antivirus software Page 21 Automatic updates Using automatic updates Windows can routinely search for the latest important updates for the device which are then automatically installed The automatic update function is activated when the device is delivered Always keep the automatic update function activated to protect the device Automatic backup Us...

Страница 24: ...Preparation for use 4 4 Operation without antivirus software SINAMICS CONNECT 500 22 Operating Instructions 10 2019 ...

Страница 25: ...al is only required if the module has to be replaced Page 43 5 2 Mounting and installation connectivity module version that can be retrofitted The instructions to mount and install the connectivity module version that can be retrofitted are provided in the Internet https support industry siemens com cs ww en ps 25520 SINAMICS CONNECT 500 Operating Instructions 10 2019 23 ...

Страница 26: ...Mounting and installation 5 2 Mounting and installation connectivity module version that can be retrofitted SINAMICS CONNECT 500 24 Operating Instructions 10 2019 ...

Страница 27: ...he IPC is installed 3 Route the LAN cable into the control cabinet 4 Route the LAN cable to the IPC Note Maintain the permissible cable bending radius Route the cable so that it does not come into contact with any sharp edges 5 Connect the LAN cable to interface X1 P1 of the IPC Interface X1 P1 6 2 Connection connectivity module version that can be retrofitted The instructions to mount and install...

Страница 28: ...Connection 6 2 Connection connectivity module version that can be retrofitted SINAMICS CONNECT 500 26 Operating Instructions 10 2019 ...

Страница 29: ...e on the service PC Deactivate the additional network interfaces or withdraw the additional LAN cable from the service PC Note When carrying out any work carefully observe the five safety rules Page 8 Procedure 1 Open the control cabinet of the converter 2 In the control cabinet locate where the IPC is installed 3 Directly and physically connect the local service PC to interface X3 P1 of the IPC u...

Страница 30: ... configuration set in the factory IP address 192 168 0 185 User name AgentAdmin Password Password Page 19 for the Windows user account 7 2 Activating the internet time Procedure 1 Open the Windows Control Panel 2 Open the date and time settings by clicking on link Date and Time 3 Click on button Change time zone 4 Set the time zone to UTC Coordinated Universal Time and confirm with OK 5 Switch to ...

Страница 31: ...first time and before installing any updates create recovery points for both partitions of the IPC Procedure 1 On the IPC desktop open folder Troubleshooting 2 Select script 11_create_recovery_point 3 In the shortcut menu execute command Run as administrator 7 4 Updating Windows After switching on the IPC for the first time perform all security relevant Windows updates Commissioning 7 4 Updating W...

Страница 32: ...omatically sources an IP address from the next accessible DHCP server When required via a Remote Desktop Connection you can deactivate DHCP for the LAN interface X1 P1 and assign a fixed IP address See also Prerequisites Page 19 7 6 Inserting the connection key on the IPC To log in to the connectivity module with SIDRIVE IQ insert the connection key on the IPC in MindConnect Bridge Prerequisites A...

Страница 33: ...ation for connecting the connectivity module to MindSphere has been configured You can read the connection status in the MindConnect Bridge application You can see that a connection has been successfully established with MindSphere in status messages Last service state MAIN and Last MCL status Success in the status line in the lower part of the program window 7 7 Replacing parameter lists and alar...

Страница 34: ...CS Plugin Plugin configuration Parameter files 3 In the right hand column click on open Dialog Parameter file configuration opens 4 Right click in field Xml File Containing Parameter Description 5 Select the shortcut menu command Select Commissioning 7 7 Replacing parameter lists and alarm lists SINAMICS CONNECT 500 32 Operating Instructions 10 2019 ...

Страница 35: ...stemConnect config SinamicsBase GM150 7 Select the parameter list that matches your firmware 8 Click on Open 9 Select menu command File Save Commissioning 7 7 Replacing parameter lists and alarm lists SINAMICS CONNECT 500 Operating Instructions 10 2019 33 ...

Страница 36: ...ugin container SINAMICS Plugin Plugin configuration Alarms and warnings 2 In the right hand column click on open Dialog Reading of Alarms and Warnings opens Commissioning 7 7 Replacing parameter lists and alarm lists SINAMICS CONNECT 500 34 Operating Instructions 10 2019 ...

Страница 37: ... lists on the Control Unit of the converter restart service Drive System Connect Page 44 7 8 Checking the connections to the converter Control Unit You can check the connections to the converter Control Unit using application Drive System Connect Diagnose Connections to the GM150 converter are checked in the following example Checking the connection 1 Open application Drive System Connect Diagnose...

Страница 38: ...ht of the program window 3 Check field Status For an existing connection the directory in which data was last backed up is displayed 4 Check the counters in table Files in column Download Count The counter values increase if a connection exists Checking the S7 connection 1 Switch to tab 01VSD1_GM150 2 Check the S7 connection to the converter in subtab Dataset If required refresh the display of the...

Страница 39: ...2 Disconnect the connection from the local service PC to the IPC to the converter Control Unit 3 Withdraw the LAN cable from the SCALANCE switch interface 4 Close the converter control cabinet Commissioning 7 9 Completing commissioning SINAMICS CONNECT 500 Operating Instructions 10 2019 37 ...

Страница 40: ...Commissioning 7 9 Completing commissioning SINAMICS CONNECT 500 38 Operating Instructions 10 2019 ...

Страница 41: ...ion with SIDRIVE IQ In operation the connectivity module captures data from the drive components and transfers this data to SIDRIVE IQ www siemens com sidrive iq for analysis SINAMICS CONNECT 500 Operating Instructions 10 2019 39 ...

Страница 42: ...Operation 8 1 Data evaluation with SIDRIVE IQ SINAMICS CONNECT 500 40 Operating Instructions 10 2019 ...

Страница 43: ...re image on the IPC with your own backup copy which was created before commissioning the connectivity module Follow the instructions provided in Chapter Inserting the connection key on the IPC Page 30 Restoring the software image on the IPC with your own backup copy which was created after commissioning the connectivity module It is not necessary to reinsert the connection key Additional informati...

Страница 44: ...sult The software and or the updates are installed and entered into the whitelist See also Prerequisites Page 19 9 3 Updating Windows Regularly and promptly loading software updates is an important element of a comprehensive security concept Software updates play an important role in ensuring stable system operation when it comes to closing security gaps that have been identified Automatic Windows...

Страница 45: ... found in Chapter Deleting the data of the connectivity module Page 44 For backing up and restoring software components carefully comply with the instructions in Chapter Updating backing up and restoring software components Page 41 Note When carrying out any work carefully observe the five safety rules Page 8 Replacement parts You can order the individual connectivity module components as replacem...

Страница 46: ...d Run as administrator The operation may take several minutes Result System related data is reliably deleted according to the NCSC TG 025 standard of the National Computer Security Center See also Documentation of the components Page 15 9 7 Fault rectification Troubleshooting information is provided in the documentation Page 15 for the particular component 9 7 1 Restart service Drive System Connec...

Страница 47: ...seen Prerequisite The service PC is in the same subnet as interface X127 of the CU Procedure 1 Open the control cabinet of the converter 2 In the control cabinet locate where the SCALANCE switch is installed 3 Directly and physically connect the local service PC to a free interface of the SCALANCE switch using a LAN cable Note You have direct access to the internal network of the connectivity modu...

Страница 48: ...y Page 53 9 7 3 Activating FTP on the Control Unit Use the STARTER commissioning software to activate FTP on the converter Control Unit Procedure 1 Open the STARTER application 2 Open the expert list of the Control Unit 3 Activate parameter p8908 Activate FTP 4 Set the online value to 1 Yes 5 Click on Copy from RAM to ROM 6 Save the settings Note The FTP server is immediately activated The FTP ser...

Страница 49: ...ity module You can order replacement parts through the regional Siemens support organization Ordering data Provide the following data when ordering replacement parts Article No MLFB of the connectivity module Serial number of the converter on which the connectivity module is mounted Article No MLFB of the converter on which the connectivity module is mounted Replacement parts The following replace...

Страница 50: ...Replacement parts 10 2 Replacement parts for the connectivity module SINAMICS CONNECT 500 48 Operating Instructions 10 2019 ...

Страница 51: ...e please contact a company certified for the disposal of electronic waste or dispose of the device in accordance with the regulations in your country The connectivity module can be recycled due to the low level of harmful substances Note Dispose of products described in this manual in compliance with the valid national regulations For environmentally compliant recycling and disposal of your discar...

Страница 52: ...m the components To do this follow the instructions in Chapter Deleting the data of the connectivity module Page 44 3 Dispose of the connectivity module according to national regulations or recycle it Disposal 11 2 Disposing of the connectivity module SINAMICS CONNECT 500 50 Operating Instructions 10 2019 ...

Страница 53: ...stry siemens com cs ww en sc 4868 Please have the following data ready Type Order number Contact person Please contact your local partner if you wish to request service This office will contact the responsible service center on your behalf You can find your local partner in the relevant contact database www siemens com yourcontact SINAMICS CONNECT 500 Operating Instructions 10 2019 51 ...

Страница 54: ...Service Support SINAMICS CONNECT 500 52 Operating Instructions 10 2019 ...

Страница 55: ...3 3 3 3 3 352 1 7 3ODQW QHWZRUN 6 0 7 3 3 3 3 063 RQQHFWLRQ 3 1RQ WUXVWHG 1HWZRUN QWHUQDO 1HWZRUN 6HFXUHG 6 1 3 6 VWHP 8 3 RU 6 6HUYLFH 3 3 H J 67 57 5 3 6 1 0 6 ULYH 3 RPPLVVLRQLQJ 5 3 QDEOHG Figure B 1 Standard topology medium voltage converter with CU320 2 SINAMICS CONNECT 500 Operating Instructions 10 2019 53 ...

Страница 56: ...Standard topology B 1 Standard topology medium voltage converter with CU320 2 SINAMICS CONNECT 500 54 Operating Instructions 10 2019 ...

Страница 57: ...e IPC 41 M Mounting and installation 23 O On site service 51 Overview 13 P Parameter lists replacing 32 Passwords 20 Q Qualified personnel 7 R Realtime protection 21 Replacement part 43 Replacement parts Ordering data 47 Spares on Web 47 Replacing Connectivity module 43 S S7 connections checking 36 Safety instructions 7 Setting recovery points 29 Setting up the IP address 30 SIDRIVE IQ 16 Spares o...

Страница 58: ...U Updating Windows 30 W Windows backup 21 Windows Security Center 21 Windows update 21 Windows updates 42 Index SINAMICS CONNECT 500 56 Operating Instructions 10 2019 ...

Страница 59: ......

Страница 60: ...Further Information www siemens com drives Siemens AG Process Industries and Drives Postfach 48 48 90026 Nürnberg DEUTSCHLAND ...

Отзывы: