Overview
Basic Operator Panel 2 (BOP-2)
Operating Instructions, 02/2016, A5E37143404B AA
15
The specific functions of the keys are shown in the following table.
Table 4- 2
Function of the BOP-2 controls
Key
Function
The OK key has the following functions:
•
When navigating through the menus, pressing the OK key confirms selection of a menu item.
•
When working with parameters, pressing the OK key allows the parameter to be modified. Pressing the OK
key again confirms the entered value and return you to the previous screen.
•
In the faults screen, the key is used to clear faults.
The UP key has the following functions:
•
When navigating a menu, the key moves the cursor up through the displayed list.
•
When editing a parameter value, the displayed value is increased.
•
If HAND mode is active and the Jog function is active; a long press of the UP and DOWN key simultaneously
has the following effects:
–
If reverse is ON the UP key switches the reverse function OFF.
–
If reverse is OFF the UP key switches the reverse function ON.
The DOWN key has the following functions:
•
When navigating a menu, the key moves the cursor down through the displayed list.
•
When editing a parameter value, the displayed value is decreased.
The ESC key has the following functions:
•
If pressed for less than 2 seconds the BOP-2 returns to the previous screen. When a displayed value has
been edited, the new value is not saved.
•
If pressed longer than 3 seconds the BOP-2 returns to the status screen.
When using the ESC key in the parameter edit mode, no data is saved unless the OK key has been pressed.
The ON key has the following functions:
•
In AUTO mode, the ON key is not active and if pressed, the key is ignored.
•
In HAND mode the Inverter starts the motor; the operator panel screen displays the drive running icon.
The OFF key has the following functions:
•
In AUTO mode the OFF key has no effect and the key press is ignored.
•
If pressed for longer than 2 seconds the Inverter performs an OFF2; the motor coasts down to a standstill.
•
If pressed for less than 3 seconds the following actions will be performed:
–
If the OFF key is press twice in less than 2 seconds on OFF2 is performed.
–
If in HAND mode, the Inverter performs an OFF1; the motor ramp-down to a standstill in the time set in pa-
rameter P1121.
The HAND/AUTO key switches the command source between the BOP-2 (HAND) and fieldbus (AUTO).
•
If HAND mode is active, the HAND/AUTO key switches the Inverter to AUTO mode and disables the ON and
OFF keys.
•
If AUTO mode is active, the HAND/AUTO key switches the Inverter to HAND mode and enables the ON and
OFF keys.
Changing between HAND mode and AUTO mode is possible while the motor is still running.
Содержание SINAMICS BOP-2
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of contents Basic Operator Panel 2 BOP 2 6 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 8: ...Changes in this manual Basic Operator Panel 2 BOP 2 8 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 12: ...Safety notes Basic Operator Panel 2 BOP 2 12 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 32: ...Diagnostics Basic Operator Panel 2 BOP 2 32 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 42: ...Setup Basic Operator Panel 2 BOP 2 42 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 48: ...Extras Basic Operator Panel 2 BOP 2 48 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 50: ...Technical data Basic Operator Panel 2 BOP 2 50 Operating Instructions 02 2016 A5E37143404B AA ...
Страница 53: ......
Страница 54: ......