Table 9-2
Error messages requiring acknowledgement
Display Error
description
F101
Over run cam static "1"
F102
Over run cam failed
F103
Over run cam static "0"
F104
Overtravel distance to long
F105
Ramp up cam failed
F106
Operating mode change not in TDC
F107
Short circuit at mode selector switch
F108
Speed monitor
F109
Runtime error, channel 1 (valve 1)
F110
Runtime error, channel 2 (valve 2)
F111
Runtime error, channel 3 (valve 3)
F112
Runtime error, channel 4 (EMERGENCY OFF output signal)
F113
Light curtain mode selection (1 cycle/2 cycle)
F114
Short circuit or "0" at light curtain mode selector switch
F115
Setting - dynamic cam
F122
Discrepancy error, transfer point
F123
Error in dynamic valve control, channel 1
F124
Error in dynamic valve control, channel 2
F125
Error in dynamic valve control, channel 3
F316
Restart inhibit, EMERGENCY OFF is set
F317
Restart inhibit, safety guard is set
F318
Restart inhibit, light curtain is set
F319
Restart inhibit, EMERGENCY OFF output signal
F320
*)
Safety gate closed – not ready for acknowledge (blocked)
F321
*)
Safety gate closed – ready for acknowledge
This error can only be acknowledged in the Setup operating mode
*)
If the safety gate display is parameterized for the fault lamp.
Содержание Simotion TM 121C
Страница 1: ...Application manual 06 2003 Edition simotion SIMOTION Safety Integrated Safety Unit TM 121C ...
Страница 2: ......
Страница 6: ... Siemens AG 2003 All Rights Reserved vi SIMOTION Safety Unit AP Edition 06 2003 Notes ...
Страница 20: ...Operating modes Siemens AG 2003 All Rights Reserved 2 20 SIMOTION Safety Unit AP Edition 06 2003 Notes ...
Страница 26: ...Safety components Siemens AG 2003 All Rights Reserved 3 26 SIMOTION Safety Unit AP Edition 06 2003 Notes ...
Страница 75: ......