© Siemens AG 2003 All Rights Reserved
SIMOTION Safety Unit (AP) - Edition 06.2003
8-63
8 General functions
8.1 Single operator/multi-operator control
Figure 8-1 Implementation of single operator/multi-operator control
In the above configuration, operating mode 2 is set for single operator/multi-
operator control. Foot switch 2 can be selected using an NO contact (it can be
deactivated). The deactivation input should be switched by the selector switch for
single operator/multi-operator control.