
Install the V ring
1. Grease the axial sealing surface. The shaft seating remains ungreased.
①
V ring
②
Mounting aid washer
③
Protective ring
Figure 9-5
Install the V ring
2. Push the V ring
①
onto the shaft using an assembly disk
②
.
The V ring is in the correct axial position when the face surface is flush with the outer edge
of the V ring.
Install the protective ring for IP56 degree of protection
For degree of protection IP56, the V ring for the outer bearing seal is fitted with a sheet steel
protective ring
③
in the bearing cover.
1. Push the protective ring onto the shaft.
2. Verify that the ring is sufficiently pretensioned. Replace the protective ring, if necessary.
3. Position the protective ring so that one of the longitudinal grooves meets the corresponding
water separation groove at the bottom in the bearing cover flange or end shield.
9.3.6.6
Installing the V ring ("Increased degree of protection" option)
The grease chamber of the labyrinth sealing ring together with the V ring ensures compliance
with degree of protection IP65.
Maintenance
9.3 Corrective maintenance
1MB5 SH 400/450
Operating Instructions, 05/2019, A5E45959221A
129
Содержание SIMOTICS XP 1MB5 SH400
Страница 2: ......
Страница 10: ...Table of contents 1MB5 SH 400 450 8 Operating Instructions 05 2019 A5E45959221A ...
Страница 64: ...Assembly 5 4 Aligning and fixing the machine 1MB5 SH 400 450 62 Operating Instructions 05 2019 A5E45959221A ...
Страница 106: ...Operation 8 8 Non operational periods 1MB5 SH 400 450 104 Operating Instructions 05 2019 A5E45959221A ...
Страница 154: ...Disposal 11 5 Disposal of components 1MB5 SH 400 450 152 Operating Instructions 05 2019 A5E45959221A ...
Страница 156: ...Service support 1MB5 SH 400 450 154 Operating Instructions 05 2019 A5E45959221A ...
Страница 160: ...Quality documents 1MB5 SH 400 450 158 Operating Instructions 05 2019 A5E45959221A ...
Страница 165: ......
Страница 166: ...Germany More information www siemens com drives Siemens AG Digital Industries Postfach 48 48 90026 NÜRNBERG ...