Electrical connection
8.3 System integration
1FW3 complete torque motors
Configuration Manual, 08/2020, A5E46027705B AA
305
Table 8- 3
Terminal box specifications
GK 230
GK 420
GK 630
GK 603
1XB7-700
1XB7-712
Diagram
Dimen-
sions
L x
W x H
122 x 117 x 62 162 x 162 x 74 210 x 210 x 117 210 x 212 x 123 306 x 306 x 160
317 x 370 x 226
Rated
current I
N
I
N
≤
50 A
50 A < I
N
<
105 A
105 A < I
N
<
260 A
I
N
≤
260 A
I
N
≤
450 A
450 A < I
N
<
830 A
Voltage
AC / DC
400 ... 480 V
400 ... 480 V
400 ... 480 V
400 ... 480 V
400 ... 480 V
400 ... 480 V
Thread
diameter
to fix
cables
M5
M10
M10
M5 / M10
M12
M16
Ground
connec-
tion
M4
M6
M10
M6 / M10
M12
M16
Remova-
ble cable
entry plate
No
No
No
Yes
Yes
Yes
Cable
entry
2 x M32 x 1.5
2 x M40 x 1.5
2 x M50 x 1.5
2 x M63 x 1.5
3 x M75 x 1.5 *
)
4 x M75 x 1.5
Maximum
possible
conductor
cross-
section
2 x 16 mm²
2 x 35 mm²
2 x 50 mm²
2 x 50 mm²
3 x 120 mm²
4 x 120 mm²
*
)
Option P01 Cable entry plate with 3 x M63 x 1.5 for 1XB7-700 terminal box
Содержание SIMOTICS T-1FW3
Страница 1: ...1FW3 complete torque motors ...
Страница 2: ......
Страница 8: ...Introduction 1FW3 complete torque motors 6 Configuration Manual 08 2020 A5E46027705B AA ...
Страница 12: ...Table of contents 1FW3 complete torque motors 10 Configuration Manual 08 2020 A5E46027705B AA ...
Страница 298: ...Preparation for use 7 2 Storing 1FW3 complete torque motors 296 Configuration Manual 08 2020 A5E46027705B AA ...
Страница 350: ...Appendix A 2 Environmental compatibility 1FW3 complete torque motors 348 Configuration Manual 08 2020 A5E46027705B AA ...
Страница 353: ......
Страница 354: ......