Connecting
6.4 System integration
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
61
Ability to rotate the connectors on motors with resolver and SMI
1
Power connector, Size 1
2
RJ45 signal connector with SMI
A
Output cam on the connector foot to limit the twistability
Figure 6-3
Ability to rotate resolver versions with SMI
Rotation range of the power connector
①
and the signal connector with SMI
②
Motor
Power connector, Size 1
①
RJ45 signal connector with
SMI
②
Drawing
Connector
size
Angle α
Angle β
Angle α´
Angle β´
1FK703
1
200°
70°
240°
5°
1FK704
175°
80°
255°
5°
1FK706
185°
85°
255°
5°
Rotation range of the power connector
①
and the RJ45 signal connector with SMI
②
Maximum rotating torque for the connectors
Connectors
Max. torque when rotating
Power connector, size 1
12 Nm
Signal connector M17
12 Nm
RJ45 signal connector with SMI
8 Nm
Maximum rotational connector torque