Electrical connection
8.3 System integration
SIMOTICS M-1FE1 synchronous built-in motors
Configuration Manual, 09/2019, A5E47872980B AA
113
8.3.1.4
Terminal boxes
The terminal box is not included in the scope of supply.
Note
The terminal box box must have as a minimum, degree of protection IP54 according to
DIN IEC 60034-5.
•
Install the corresponding seals between the spindle box and terminal box, as well as
at the terminal box cover.
8.3.1.5
Recommended grounding
Note
A protective conductor / bearing shield must be connected at the spindle box through a
good electrical connection.
The spindle housing / bearing shield must be electrically connected to the cooling jacket.
•
Use a protective conductor with the required minimum cross-section.
•
Ground so there is a good conductive transition between the protective conductor and
spindle box protected against corrosion (e.g. bare contact surfaces with a coating of
Vaseline).
1
Stator
2
Cooling jacket
3
Spindle housing
4
Bearing shield
5
Ground connection with M8 screw
Figure 8-3 Recommended grounding
Содержание Simotics M-1FE1 Series
Страница 1: ...SIMOTICS M 1FE1 synchronous built in motors ...
Страница 2: ......
Страница 12: ...Table of contents SIMOTICS M 1FE1 synchronous built in motors 10 Configuration Manual 09 2019 A5E47872980B AA ...
Страница 22: ......
Страница 46: ......
Страница 52: ......
Страница 78: ......
Страница 82: ......
Страница 146: ...List of abbreviations SIMOTICS M 1FE1 synchronous built in motors 144 Configuration Manual 09 2019 A5E47872980B AA ...
Страница 149: ......
Страница 150: ......