Electrical connection
6.8 Final checks
Standard motors SH 63 ... 355
Operating Instructions, 12/2018, A5E38483075A
73
Table 6- 5
Maximum voltage peaks at the motor terminals for line (DOL) motors, converter operation possible
Rated motor voltage
V
Maximum peak voltage at the motor terminals
Û
max
dependent on the rise time t
r
Û
phase-to-phase
V
pk
Û
phase-to-ground
V
pk
Rise time t
r
μs
DC link U
DC
V
≤ 500
V
1500
1100
0.5
750
900
900
0.1
Table 6- 6
Maximum voltage peaks at the motor terminals for motors specifically designed for converter operation (e.g.
VSD 10)
Rated motor voltage
V
Maximum peak voltage at the motor terminals
Û
max
dependent on the rise time t
r
Û
phase-to-phase
V
pk
Û
phase-to-ground
V
pk
Rise time t
r
μs
DC link U
DC
V
≤ 500
V
1600
1400
0.5
750
1000
1000
0.1
> 500 V to 690 V
2200
1800
0.5
1080
1000
1000
0.1
See also
Further documents (Page 140)
6.8
Final checks
Before closing the terminal box/terminal base of the machine enclosure, check the following:
●
Establish the electrical connections in the terminal box in accordance with the information
in this documentation.
●
Maintain the air clearances between non-insulated parts as described in Chapter
Minimum air clearances. (Page 66)
●
Avoid protruding wire ends.
●
In order not to damage the cable insulation, freely arrange the connecting cables.
●
Connect the machine corresponding to the specified direction of rotation.
●
Keep the inside of the terminal box clean and free from trimmed-off ends of wire.
●
Ensure that all seals and sealing surfaces are undamaged and clean.
●
Correctly and professionally close unused openings in the terminal boxes. Observe the
information in this documentation.
●
Observe the information on torques in this documentation.
See also
Tightening torques for screw and bolt connections (Page 141)
Содержание SIMOTICS DP series
Страница 1: ......
Страница 2: ......
Страница 62: ...Assembly 5 4 Installing the machine Standard motors SH 63 355 60 Operating Instructions 12 2018 A5E38483075A ...
Страница 86: ...Commissioning 7 2 Switching on Standard motors SH 63 355 84 Operating Instructions 12 2018 A5E38483075A ...
Страница 98: ...Operation 8 7 Deactivating Standard motors SH 63 355 96 Operating Instructions 12 2018 A5E38483075A ...
Страница 118: ...Maintenance 9 3 Corrective maintenance Standard motors SH 63 355 116 Operating Instructions 12 2018 A5E38483075A ...
Страница 140: ...Disposal 11 6 Disposal of components Standard motors SH 63 355 138 Operating Instructions 12 2018 A5E38483075A ...
Страница 150: ......