Operation
8.2 Safety instructions
Smoke extraction motors
64
Operating Instructions, 03/2016, 5 610 80000 40 018
NOTICE
Risk of corrosion due to condensation
If the machine and/or ambient temperatures fluctuate, this can result in condensation inside
the machine.
•
If available, remove the drain plugs or screws to drain the water depending on the
ambient and operating conditions.
•
If available, re-attach the drain plugs or screws.
If the motor is equipped with drain plugs, then the water can drain away by itself.
Switching on the machine with anti-condensation heating (optional)
CAUTION
Machine overheating
Minor injury or material damage can occur if you do not observe the following:
•
If available, switch off the anti-condensation heating each time before switching on.
8.2.2
Safety instructions when operating machines with fan
CAUTION
Risk of injury when touching the fan
There is a risk of injury at machines equipped with a fan cover (e.g. fan cover used in the
textile industry), as the fan is not completely touch protected.
•
Do not touch the rotating fan.
•
Do not put your fingers into the larger air discharge openings.
•
Manual intervention must be prevented on the customer's side by using suitable
measures, e.g. appropriate housings or a protective grating.
8.2.3
Machines with textile fan covers
In order to guarantee an essentially unobstructed flow of cooling air containing fluff, remains
of materials or similar dirt, machines with a fan cover for textile applications have a larger air
discharge cross-section between the edge of the cover and the cooling ribs of the machine
frame.
These machines have a warning sticker on the fan cover.