Preparing for use
4.7 Converter operation
Smoke extraction motors
28
Operating Instructions, 03/2016, 5 610 80000 40 018
4.7
Converter operation
4.7.1
Parameterizing the converter
●
If the design of the motor requires connection to a particular converter type, the rating
plate will contain corresponding additional information.
●
Correctly parameterize the converter. Parameterizing data can be taken from the
machine rating plate (not the supplementary rating plate with the operating data when
connected to a converter).
You can find parameter data here:
–
In the operating instructions for the converter.
–
In the SIZER engineering tool
–
In the SINAMICS Configuration Manuals.
–
For explosion-protected machines, also in the declaration of compliance with the order
2.1.
●
Do not exceed the specified maximum speed limit n
max
. You can either find this on the
rating plate n
max
, on the supplementary plate for converter operation as the highest
speed, or in the type-specific catalog.
●
Operate the machine only for a short period at the maximum speed. Operating the
machine for an extended period at the maximum speed may cause vibrations with an
increased frequency and consequently higher noise levels.
●
Check that the machine is cooled sufficiently for commissioning purposes.
4.7.2
Reducing bearing currents during operation with converter (low voltage)
Taking the following actions will reduce the bearing currents:
●
Ensure that the contacts are established over a large area. Solid copper cables are not
suitable for high frequency grounding because of the skin effect.
Equipotential bonding conductors:
Use equipotential bonding conductors:
●
Between motor and driven machine
●
Between motor and converter
●
Between the terminal box and the RF grounding point at the motor enclosure.