14
Binary outputs
Via isolated solid-state relay
Permissible voltage
230 V/AC; 250 V/DC
Permissible current
100 mA continuous
300 mA for 100 ms
Internal resistance
50
Ω
Permissible operating
frequency
10 Hz
Analog outputs
(optional, only 7KG7660)
Nominal output current
0 to 20 mA DC
Output range
0 to 24 mA DC
Max. load resistance
250
Ω
Accuracy
0.2% (typical); max. 1.1% of the
nominal value
Relay outputs
(optional, only 7KG7660)
Rated voltage
250 V AC / 150 V DC
Max. permanent current
5 A
Min. permanent current
0,1 mA at 100 mV DC
Rating (resistive)
5 A / 250 V AC or 5 A / 30 V DC
Max. response time
10 ms
Max. release time
7 ms
Overvoltage category
According to IEC 61010 Part1
V
IN
to 480 V (L-L)
Cat III
V
IN
to 600 V (L-L)
Cat II
Power Supply
Cat II
Binary outputs, binary inputs
and relay outputs
Cat II
Содержание SIMEAS P 7KG7550