Cons.
No.
Message
Bit No.
Starting at
Diagnostic
Byte 0 (DP)
Description
Possible Remedies
13
Error
Training
Code
10
The code was not legible
and could not be saved.
Check the following potential source of
error and make corrections as
necessary:
•
There was no code in the sensor
field of view.
•
The code was not completely in
the sensor field of view.
•
The code was too close to the
edge of the field of view (2 dots
minimum clearance are
necessary).
•
The dot size is too small.
•
The dot size is too large.
•
The image is too bright or too
dark, the code visible to the sensor
is damaged.
•
The code is damaged or defective.
•
It is a die-punched code.
•
The viewing angle to the code is
too steep. The permitted angle is
between 0 and 45 degrees to the
vertical.
•
The dot type is not correctly
configured
14
Error Match
Mismatch
11
You are attempting to train
a code that does not match
the settings made in
Settings>Match.
Check the values in Settings>Match
and make sure that these are valid for
the code you want to read.
Example: There must be a specified ID
in the data matrix code.
15
Error
No ECC200
Code
12
You are attempting to train
a code that does not comply
with the ECC200 standard
or is base256 coded.
Other possible error: The
code you are reading has
print errors so that the code
cannot be identified as
ECC200 code (without
base256).
Use a data matrix coding conforming
with ECC200. (Base256 of the
ECC200 standard is also not
supported).