![Siemens SIMATIC VS130 Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431023.webp)
Installation
Vision Sensor VS 130
A5E00199459-01
3-3
3.2 Wiring
Components
Connect the processing unit with the other components using the connectors on
the front panel. The pinning of the connectors is described in Appendix A.5.
!
Caution!
Do not connect or disconnect cables when the power supply is on.
Apart from the RS-232 cable (6ES7 901-1BF00-0XA0) all the cables are supplied
(see Appendix A.1).
!
Warning
Grounding the VS 130 cancels the ungrounded installation of the power unit used
to operate the VS 130.
SE
N
S
O
R
RS232
DI
/D
O
LAMP
IN DC 24V
DP
Connector
Connector Label
Type
Number
of
pins
Cable Cross
Section
Type
Functional earth
-
Screw terminal
-
-
-
Power supply
IN DC 24 V
Circular connector M12
4
0.56 mm
2
Pin
Lighting unit
LAMP
Circular connector M12
4
0.23 mm
2
Socket
Sensor head
(shielded cable)
SENSOR
HD Sub D *
26
0.09 mm
2
Socket
I/O
DI/DO
Sub D
15
0.14 mm
2
Socket
RS-232
RS-232
Sub D
9
-
Pin
PROFIBUS DP
PROFIBUS DP
Sub D
9
-
Socket
* The supplied ferrite ring must be fixed to the sensor cable (approx. 50 mm from connector to