Information
Form
No.
Display
Description
2
C 02 READS
=3226
=99.907%
2/6
↕
OK
Since the last start, the code 02 was decoded successfully 3226
times. This corresponds to 99.907 % of all read operations since the
last evaluation startup.
3
C 02 N_OK
=3
=0.093%
3/6
↕
OK
Since the last start, the code 02 could not be decoded 3 times. This
corresponds to 0.093 % of all read operations since the last
evaluation startup.
4
C 02 MATCH
=3226
=99.907%
4/6
↕
OK
Since the start of evaluation, the substring of the learned code 02
specified in the "Match" submenu was found 3226 times in the read
codes. This corresponds to 99.907 % of all read operations since the
last evaluation startup.
5
C 02 Curr.
Cycletime
=300ms
5/6
↕
OK
The evaluation time required for the read code (code 02) (current
cycletime)
6
C 02 Cycle
Too Short
=0.072%
6/6
↑
OK
Since the start of the evaluation, the time available for evaluating the
read code (cycletime) was not adequate in 0.072 % of all read
operations.
Note:
This information form is used in particular for monitoring when the
evaluation time of the read code is of a similar length to the time
available (cycletime). If you have set the cycle time too low, the
percentage shown here will be reflected in the percentage shown in
information form no. 3. In this case, increasing the cycle time will
improve the detection rate.