Installing the Module
2-2
High Speed Counter Encoder Module User Manual
2.1
Overview of Installation
Figure 2-1 shows the flow of tasks to follow when you install this module.
Configure counter mode of operation (See Chapters 3, 4, and 5.)
Chapter 4 describes the default configuration of the module.
Insert module into I/O base.
Connect I/O wiring to the terminal block.
Power up and check status of LEDs.
Configure I/O address in controller memory.
Figure 2-1
Flowchart of Installation
Many integrated circuit (IC) devices are susceptible to damage by the
discharge of static electricity. Follow the precautions below to reduce the
probability of damage when you are handling the HSCE module, the
controller, or any of the I/O modules.
Take the following precautions to help ensure that you and the module are
at the same ground potential.
•
Transport the module in an anti-static container or in anti-static
material.
•
Ensure that the work area has a conductive pad with a lead connecting
it to a common ground.
•
Ground yourself by making contact with the conductive pad and/or by
wearing a grounded wrist strap
If there is any visible damage to the module, contact your vendor for
replacement.
Flow of Tasks
Handling the
Module
Visual Inspection