36. Add a new function block (FB1).
36
37. Select "GPS position" as the function.
38. Interconnect the parameters as follows:
–
Position: System location
–
Radius (m): 1000
–
Output: gpsPosition (DM2)
–
Distance: distance (AM2)
37
38
38
38
39. Add a new function block (FB2) below it.
39
40. Select "Send SMS" as the function.
41. Interconnect the parameters as follows:
–
Trigger: gpsPosition (DM2)
–
Send immediately: True
–
Recipient: Administrator SMS
–
Text: gpsPositionOK
40
41
41
42. Add a new function block (FB3) below.
42