"RF650M" software
6.7 The functions in the "Settings" menu
SIMATIC RF650M mobile reader
Operating Instructions, 04/2015, C79000-G8976-C404-01
55
Parameter
Setting options
Default value
Description
TX Power
•
500 mW
•
398 mW
•
316 mW
•
251 mW
•
200 mW
•
158 mW
•
126 mW
•
100 mW
•
79 mW
•
63 mW
•
50 mW
•
40 mW
•
32 mW
•
25 mW
•
20 mW
•
16 mW
•
13 mW
•
10 mW
•
8 mW
•
6 mW
500 mW
The transmit power (TX Power)
essentially decides the size of the
identification range for transpond-
ers.
TX Modulation
•
ASK
•
PR-ASK
PR-ASK
Modulation method.
This setting should only be
changed by experienced and
trained RFID users.
RX Decoding
•
FM-0
•
Miller-2
•
Miller-4
•
Miller-8
Miller-4
This setting should only be
changed by experienced and
trained RFID users.
Antenna
•
Auto
•
Antenna 1
Auto
The integrated turnstile antenna
can be set to a fixed polarization. It
is recommended that you leave the
value at "Auto" since with this tran-
sponders in different positions or
dipole directions can be identified.