Advanced
In the "Advanced" tab, you can specify the locate parameters. During scanning, only the
transponders identified by the reader and whose parameters match the specified locate
parameters are shown in the transponder list. You can, for example, locate transponders that
use a special chip type or transponders, for example, whose EPC starts with the value "3".
Figure 6-11 "Advanced" tab in the "Tag Locator" menu
Table 6- 10 Parameters of the "Advanced" tab
Parameter
Setting options
Default value
Description
Bank
•
Reserved
•
EPC
•
TID
•
User
EPC
Selection of the memory bank in
which a locate criterion should be
met.
Start [b]
0 ... 65535
32
Start address of the locate criterion
in bits
Length [b]
0 ... 65535
0
Length of the locate criterion start-
ing from the start address
Mask
00000000 ...
FFFFFFFF
--
Desired value of the locate criteri-
on
1)
Locate
--
--
Changes to the locate mode. In the
locate mode the received signal
strength is displayed with which
the target transponder was identi-
fied.
Scan
--
--
Starts/stops scanning. All identified
transponders are displayed in the
transponder list.
1)
From the list in the lower area, you can select the preset transponder chip types.
Содержание SIMATIC RF650M
Страница 6: ...Introduction SIMATIC RF650M mobile reader 6 Operating Instructions 04 2015 C79000 G8976 C404 01 ...
Страница 8: ...Safety Information SIMATIC RF650M mobile reader 8 Operating Instructions 04 2015 C79000 G8976 C404 01 ...
Страница 72: ...Ordering data SIMATIC RF650M mobile reader 72 Operating Instructions 04 2015 C79000 G8976 C404 01 ...