SIMATIC RF310M software
8.5 The functions in the "Tag" menu
SIMATIC RF310M Mobile Reader
Operating Instructions, 10/2013, J31069-D0191-U001-A6-7618
47
8.5.2
Reading the tag configuration data
You can read the configuration data of a tag by selecting the memory area "CONFIG" in the
editor and subsequently carrying out a read operation. The memory area "CONFIG" only
exists with RF300 tags.
Byte address
EEPROM
Functional description
0xFF1f
Bank switch (bits 1 and 0)
Memory bank
0xFF1e
MDS delay (bits 7:5); LFD (bit 4)
MDS delay/LFD bit
0xFF1d
Reserved
0xFF1c
Limit value A for LFD quotients
LFD (A)
0xFF1b
Limit value B for LFD quotients
LFD (B)
0xFF1a
Reserved
0xFF19
Memory configuration, INIT (bits
7...1)
Memory configuration/Init bit
0xFF18
Range for lock bits
Lock bits
0xFF17
Tag ID, byte 3
Tag ID (b24-b31)
0xFF16
Tag ID, byte 2
Tag ID (b16-b23)
0xFF15
Tag ID, byte 1
Tag ID (b8-b15)
0xFF14
Tag ID, byte 0
Tag ID (b0-b7)
8.5.3
Read tag status
You can read and display the status data of the transponder via "Tag > Tag Status".
The following tag status information is displayed here:
●
Tag ID
●
FRAM memory size in bytes
●
Lock bit register (8-bit binary value)
●
ASIC version
Содержание SIMATIC RF310M
Страница 1: ......
Страница 2: ......
Страница 100: ...Technical Specifications SIMATIC RF310M Mobile Reader 100 Operating Instructions 10 2013 J31069 D0191 U001 A6 7618 ...
Страница 102: ...Ordering data SIMATIC RF310M Mobile Reader 102 Operating Instructions 10 2013 J31069 D0191 U001 A6 7618 ...
Страница 108: ...Appendix A 5 Service Support SIMATIC RF310M Mobile Reader 108 Operating Instructions 10 2013 J31069 D0191 U001 A6 7618 ...
Страница 114: ......