6.5.10
Upgrading with OPC A&E
6.5.10.1
Updating PCS 7 projects with OPC A&E
As of PCS 7 V7.0 SP1, OPC A&E has been expanded to include hierarchical access to the
message system.
You can continue to use the non-hierarchical OPC A&E server.
Updating OPC A&E
If you use OPC A&E with hierarchical access and want to use all functions, an expansion of
the currently used OPC A&E client is necessary.
Starting from the PCS 7version of your project, various scenarios for updating projects with
OPC A&E are described below.
6.5.10.2
How to update an OPC project with PCS 7 V8.0
Options
The following options are available for updating a PCS 7 project with configured access via
OPC A&E to PCS 7 V8.0 OpenPCS 7 station:
● Conversion to OPC A&E with hierarchical access
● Retain OPC A&E without hierarchical access
Requirement
The PCS 7version of the project to be updated is PCS 7 V6.1 SP2 or higher.
Preparation
Before performing the update, delete any "CCAeProvider.ini" file on the OS server or on the
ES directly in the OS project folder.
You can find the OS project folder in "wincproj" subfolder on the engineering station.
Conversion to OPC A&E with hierarchical access
No adjustments need be made for the conversion to OPC A&E with hierarchical access. OPC
A&E with hierarchical access is the default setting.
OpenPCS 7 interface
6.5 OPC Alarms and Events (OPC A&E)
OpenPCS 7
Function Manual, 05/2012, A5E02780178-02
73