background image

Table of Contents

5

Technical Specifications ......................................................................................................  45

5.1

Power Supply Specifications ................................................................................  45

5.2

Failsafe Relay Specifications ................................................................................  45

5.3

Operating Environment ....................................................................................... 46

5.4

Mechanical Specifications .................................................................................... 46

5.5

Dimension Drawings ...........................................................................................  46

6

Certification ......................................................................................................................... 49

6.1

Approvals ............................................................................................................ 49

6.1.1

TÜV SÜD .............................................................................................................  49

6.1.2

European Union (EU) ..........................................................................................  49

6.1.3

FCC .....................................................................................................................  50

6.1.4

FDA/CDRH ...........................................................................................................  51

6.1.5

ISED ....................................................................................................................  51

6.1.6

ANATEL ............................................................................................................... 51

6.1.7

ISO ...................................................................................................................... 52

6.1.8

RoHS ................................................................................................................... 52

6.1.9

Other Approvals ..................................................................................................  52

6.2

EMC and Environmental Type Tests ..................................................................... 53

iv

RUGGEDCOM RX1511

Installation Manual, 04/2021, C79000-G8976-1056-20

Содержание SIMATIC NET

Страница 1: ...Edition 04 2021 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1511 https www siemens com ...

Страница 2: ...ugged Multi Service Platforms RUGGEDCOM RX1511 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 04 2021 C79000 G8976 1056 20 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...evice 5 2 1 General Procedure 6 2 2 Unpacking the Device 6 2 3 Mounting the Device 7 2 3 1 Mounting the Device on a DIN Rail 7 2 3 2 Mounting the Device to a Panel 8 2 4 Connecting the Failsafe Alarm Relay 9 2 5 Connecting Power 10 2 5 1 Connecting High AC DC Power 11 2 5 2 Connecting Low DC Power 14 3 Device Management 19 3 1 Connecting to the Device 19 3 2 Configuring the Device 21 3 3 Accessing...

Страница 5: ...echanical Specifications 46 5 5 Dimension Drawings 46 6 Certification 49 6 1 Approvals 49 6 1 1 TÜV SÜD 49 6 1 2 European Union EU 49 6 1 3 FCC 50 6 1 4 FDA CDRH 51 6 1 5 ISED 51 6 1 6 ANATEL 51 6 1 7 ISO 52 6 1 8 RoHS 52 6 1 9 Other Approvals 52 6 2 EMC and Environmental Type Tests 53 iv RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 6: ...es https support industry siemens com cs ww en view 109747072 RUGGEDCOM SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Accessing Documentation The latest user documentation for RUGGEDCOM RX1511 is available online at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Registered Trademarks RUGGEDCOM RO...

Страница 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...

Страница 8: ...ncluding FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 10: ...rsh Environments Immunity to EMI and high voltage electrical transients 40 to 85 C 40 to 185 F operating temperature no fans Failsafe output relay for critical failure or error alarming Universal Power Supply Options Single removable power supply module Fully integrated power supplies no external adapters Input voltage ranges 13 36 VDC and 37 72 VDC or 85 264 VAC and 88 300 VDC for worldwide opera...

Страница 11: ...o the Device Page 19 Utility USB Port Use the USB port to upgrade the RUGGEDCOM RX1511 software or install files such as configuration files and feature key files For more information refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1511 Lamp Test Alarm Cut Off LT ACO Button This button performs two functions Press and hold this button to test all indicator LEDs Press and releas...

Страница 12: ...crewdriver For mounting the device to a DIN rail Phillips screwdriver For mounting the device to a panel 4 x 6 32 screws For mounting the device to a panel Braided or equivalent ground wire For grounding the device to safety Earth 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to...

Страница 13: ...nes system designers and integrators should refer to the Telecommunications Industry Association TIA TIA EIA 568 A wiring standard that characterizes minimum cabling performance specifications required for proper Gigabit Ethernet operation For reliable error free data communication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summariz...

Страница 14: ... 47 CFR section 1 1307 addressing Radio Frequency RF exposure from radio frequency base stations as defined in FCC OET Bulletin 65 http transition fcc gov Bureaus Engineering_Technology Documents bulletins oet65 oet65 pdf The emitted radiation should be as little as possible To achieve minimum RF exposure install the device when it is configured not to transmit and set it to operational mode remot...

Страница 15: ...nment of the device including maintaining the integrity of all protective conductor connections and checking equipment ratings Make sure to review all operating and installation instructions before commissioning or performing maintenance on the device 1 Review the relevant certification information for any regulatory requirements For more information refer to Approvals Page 49 2 Review the RUGGEDC...

Страница 16: ... all open sides of the device to allow for some convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Dimension Drawings Page 46 2 3 1 Mou...

Страница 17: ...igure 2 1 DIN Rail Mounting 2 Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RX1511 can be equipped with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws 8 RUGGEDCOM RX1511 Installat...

Страница 18: ... based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1511 One common application for this relay is to signal an ala...

Страница 19: ...GER Electrocution hazard risk of serious personal injury or death Make sure all power sources are off before servicing the power module terminals NOTICE Use minimum 16 gage copper wiring when connecting terminal blocks The maximum wire length between the terminal block and power source must not exceed 6 m 20 ft for 24 V power supplies or 18 m 60 ft for 48 V power supplies For 125 230 VAC rated equ...

Страница 20: ...k of death serious personal injury and or damage to the device Make sure the supplied cover is always installed over high voltage screw terminal blocks NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 11 ...

Страница 21: ...rminal Figure 2 4 AC Terminal Block Wiring European style Euroblock Terminal Block for HIP Power Supplies 3 4 5 6 5 2 1 4 1 6 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Live L Terminal 5 Ground Terminal 6 Negative Neutral N Terminal Figure 2 5 AC Terminal Block Wiring Screw Terminal Block for HI Power Supplies 12 RUGGEDCOM RX1511 Installation M...

Страница 22: ...itive live L terminal on the terminal block 3 Connect the negative wire from the power source to the neutral negative N terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1511 Device Figure 2 6 Assembling the Safety Cover 5 Using a braided wire or other appropriate grounding wire connect the ground...

Страница 23: ...ction Figure 2 7 Ground Connection 7 Install the safety cover over the terminal block 2 5 2 Connecting Low DC Power To connect a low DC power supply to the device do the following NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur Note The RUGGEDCOM RX1511 works with both positive...

Страница 24: ...erminal 3 Negative Terminal 4 Ground Terminal Figure 2 8 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 1 5 1 2 3 4 5 6 4 6 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal 5 Negative Terminal RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 15 ...

Страница 25: ...Euroblock Terminal Block 2 Positive Terminal 3 Negative Terminal 4 Ground Terminal Figure 2 10 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 5 2 3 4 5 6 1 4 1 6 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal 16 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 26: ... mm 0 28 in Make sure no bare metal is exposed beyond the safety cover 2 Connect the positive wire from the power source to the positive terminal on the terminal block 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1511 Device Fi...

Страница 27: ... the device Make sure the lug is tightened to 2 4 N m 9 5 lbf in 3 2 1 4 1 10 Ring Lug 2 10 32 Screw 3 Connection from External Power Source 4 Ground Connection Figure 2 13 Ground Connection 6 Install the safety cover over the terminal block This is mandatory for 48 VDC and 48 VDC power supplies 18 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 28: ...J45 connectors the slots on the connector where the contacts connect is too short causing the connector pins in the port to lift before a proper connection is made It is determined the minimum slot length must be 5 5 mm 0 216 in 5 5 mm Adjusting the position of the connector in the port either by wiggling or pulling the connector back corrects the issue temporarily but is not recommended It may ca...

Страница 29: ...d 8 7 RTS b Read to Send 9 RI c Ring Indicator a The DSR DCD and DTR pins are connected together internally b The CTS and RTS pins are connected together internally c RI is not connected For information about how to connect to the device via the serial console port refer to the RUGGEDCOM ROX CLI Configuration Manual for the RUGGEDCOM RX1511 For information about how to connect to the device via th...

Страница 30: ...3 3 Accessing the CompactFlash Card The RUGGEDCOM RX1511 features a removable CompactFlash CF card that stores configuration files firmware active and backup versions file based feature keys and other system files NOTICE Configuration hazard risk of data corruption loss Do not remove or insert the CF card when the device is powered on The CF card should only be removed in the following scenarios T...

Страница 31: ...evice is powered down 2 Remove the CF card access panel 3 Insert the CF card into the slot until it is fully seated 2 3 1 1 CompactFlash Card 2 Access Panel Figure 3 3 Inserting the CF Card 4 Secure the CF card access panel to the chassis Removing the CF card To remove the CF card from the device do the following 1 Make sure the device is powered down 22 RUGGEDCOM RX1511 Installation Manual 04 202...

Страница 32: ... 2 3 1 1 Ejector Button 2 CompactFlash Card 3 Access Panel Figure 3 4 Removing the CF Card 3 Press the ejector button to the left of the CF card and then pull the card out 4 Secure the CF card access panel to the chassis RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 23 ...

Страница 33: ...Device Management 3 3 Accessing the CompactFlash Card 24 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 34: ...g platform for running third party applications directly from within the RUGGEDCOM RX1511 is also available Use the RUGGEDCOM ROX software to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROX Configuration Manual for the device 4 1 Requirements and Restrictions Before installing modules in the device consider the following restrictions and requirement...

Страница 35: ...ns Input Range 9 to 15 VDC Terminal Type Removable Screw Article Numbers 6GK6015 0AL17 0AA0 Standard 6GK6015 0AL17 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 12P Specifications Input Range 9 to 15 VDC Terminal Type European style Euroblock Article Numbers 6GK6015 0AL18 0AA0 Standard 6GK6015 0AL18 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 24 shipped until 2019 Specifications Input Range 13 to 36...

Страница 36: ...ut Range 36 to 72 VDC Terminal Type Removable Screw Article Numbers 6GK6015 0AL12 0AA0 Standard 6GK6015 0AL12 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 48P Specifications Input Range 36 to 72 VDC Terminal Type European style Euroblock Article Numbers 6GK6015 0AL15 0AA0 Standard 6GK6015 0AL15 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS HI shipped until 2019 Specifications Input Range 88 to 300 VD...

Страница 37: ...4 W Article Numbers 6GK6015 0AL20 0FC0 Standard 6GK6015 0AL20 0FC1 Conformal Coated RUGGEDCOM RX1500PN LM CG03 Specifications Ports 2 Speed 1000 Mbps Interface TX Port Type M12 8 Pin A Coded Distance 100 m 328 ft Power Consumption 4 W Article Numbers 6GK6015 0AL20 0PB0 Standard 6GK6015 0AL20 0PB1 Conformal Coated RUGGEDCOM RX1500PN LM CG03B Specifications Ports 2 Speed 1000 Mbps Interface TX Port ...

Страница 38: ...tance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 0PC0 Standard 6GK6015 0AL20 0PC1 Conformal Coated RUGGEDCOM RX1500PN LM 4TX03B Specifications Ports 4 Speed 100 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled Bypass Distance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 0PF0 Standard 6GK6015 0AL20 0PF1 Conformal Coated RUGGEDCOM RX1500PN LM 4TX04 S...

Страница 39: ...ifications Mode MM Speed 100 Mbps Interface FX Wavelength 1300 nm Ports 4 Port Type LC Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BC0 Standard 6GK6015 0AL20 0BC1 Conformal Coated RUGGEDCOM RX1500PN LM FL01 Specifications Mode MM Speed 10 100 Mbps Interface FL SX Wavelength 820 nm Ports 3 Port Type ST Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 ...

Страница 40: ...Specifications SFP Sockets 4 Speed 100 Mbps Power Consumption 5 W Article Numbers 6GK6015 0AL20 0JC0 Standard 6GK6015 0AL20 0JC1 Conformal Coated RUGGEDCOM RX1500PN LM FX51 Specifications Mode SM Speed 100 Mbps Interface FX Wavelength 1310 nm Ports 2 Port Type LC Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BJ0 Standard 6GK6015 0AL20 0BJ1 Conformal Coated RUGGEDCOM RX1...

Страница 41: ...ed RUGGEDCOM RX1500PN LM TC2 Specifications Interface T1 E1 Ports 2 Port Type RJ48C Power Consumption 3 W Article Numbers 6GK6015 0AL20 0MC0 Standard 6GK6015 0AL20 0MC1 Conformal Coated RUGGEDCOM RX1500PN LM TC4 Specifications Interface T1 E1 Ports 4 Port Type RJ48C Power Consumption 3 W Article Numbers 6GK6015 0AL20 0MD0 Standard 6GK6015 0AL20 0MD1 Conformal Coated RUGGEDCOM RX1500PN LM E02 Speci...

Страница 42: ...SM EDGE HSPA Region North America AT T European Union Australia Port Type 50 Ω SMA Antennas 2 x GSM EDGE HSPA 2 x Receive Diversity Secondary SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WC0 Standard 6GK6015 0AL20 0WC1 Conformal Coated RUGGEDCOM RX1500PN LM W21 Specifications Services EVDO Rev A Region North America Verizon Port Type 50 Ω SMA Antennas 1 x EVDO Rev A 1...

Страница 43: ... 6GK6015 0AL20 0WF1 Conformal Coated RUGGEDCOM RX1500PN LM W41 Specifications Services 4G LTE HSPA HSDPA HSUPA DC HSPA UMTS WCDAM EDGE GPRS GSM GNSS Region European Union Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WG0 Standard 6GK6015 0AL20 0WG1 Conformal Coated RUGGEDCOM RX1500PN LM W51 Specifications Se...

Страница 44: ...sia Pacific Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK60150AL200WK0 Standard 6GK60150AL200WK1 Conformal Coated RUGGEDCOM APE Modules RUGGEDCOM RX1500PN LM APE1402 Obsolete Specifications Operating System Debian Linux Processor Intel Atom E660 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 8 GB SATA Solid ...

Страница 45: ...solete Specifications Operating System Debian Linux Processor Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphics Processor DVI D Power Consumption 10 W Article Numbers 6GK6015 0AL20 0GD0 Standard 6GK6015 0AL20 0GD1 Conformal Coated RUGGEDCOM RX1500PN...

Страница 46: ...ntel 4108 Graphics Processor DVI D Power Consumption 10 W Article Numbers 6GK6015 0AL20 0GE0 Standard 6GK6015 0AL20 0GE1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404CKP Obsolete Specifications Operating System Check Point GAiA OS Processor Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface U...

Страница 47: ... GB DDR3 ECC 1600 MHz 64 bit Disk 64 GB Solid State Networking Intel I210 RJ45 Gigabit Ethernet Interface USB 2 x USB 3 0 Video Intel HD Graphics Processor Display Port Power Consumption 12 W Article Numbers 6GK6015 0AL20 0GJ0 Standard 6GK6015 0AL20 0GJ1 Conformal Coated RUGGEDCOM RX1511PN LM APE1808ADM Specifications Operating System Debian Linux Processor Intel x5 E3940 1 8 GHz 2 MB L2 Cache RAM...

Страница 48: ...mption is 500 mA at 5 V Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers 6GK6015 0AL10 0AA0 Standard 6GK6015 0AL10 0AA1 Conformal Coated RUGGEDCOM RX1500PN LM Blank Specifications Article Numbers 6GK6015 0AL20 0AA0 Standard 6GK6015 0AL20 0AA1 Conformal Coated 4 3 Installing Removing Line Modules Upon installing a new line module in the device all features associated with the ...

Страница 49: ...m power consumption of each line module refer to Available Modules Page 26 NOTICE Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that may lead to premature equipment failure Always make sure slots are not left empty and open ports are protected with plugs or covers Note Only one WAN line module is supported per chassis Removing a Module To remove ...

Страница 50: ...a new module or a blank module to prevent the ingress of dust and dirt 5 Optional If necessary install the device in the rack Installing a Module To install a line module do the following 1 Optional If the device is installed in a rack remove it from the rack 2 Remove the current module from the slot RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 41 ...

Страница 51: ...re 4 3 Installing a Module 4 Tighten the screws to secure the module 5 Optional If necessary install the device in the rack 4 4 Installing Removing Power Modules The RUGGEDCOM RX1511 supports a single power module 1 1 Power Module Figure 4 4 Power Module 42 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 52: ...fore servicing the power supply terminal 1 Turn off power to the module 2 Loosen the screws that secure the module to the chassis until the module can be removed 1 2 3 1 Chassis 2 Power Supply 3 Screws Figure 4 5 Removing a Power Supply 3 Slide the module out of the chassis 4 Disconnect the power supply wiring from the terminal block Alternatively for convenience remove the terminal block with the...

Страница 53: ...dule For more information refer to Connecting Power Page 10 4 Insert the module into the empty slot 1 2 3 1 Chassis 2 Power Module 3 Screws Figure 4 6 Installing a Power Module 5 Hand tighten the screws to secure the power module to the chassis 6 Turn on power to the device and confirm the module is receiving and supplying power This is indicated by the LEDs on the module LED State Description O G...

Страница 54: ...65 W 2800 VDC for 1 minute 24 24P 13 VDC 36 VDC 10 A T b 63 5 W 48 48P 36 VDC 72 VDC 3 15 A T b 60 W 1500 VDC for 1 minute 12 12P 9 VDC 15 VDC 12 A 67 W 1500 VAC or 2121 VDC for 1 minute a Power consumption varies based on the device configuration A typical RUGGEDCOM RX1511 chassis will consume approximately 35 W of power b T denotes time delay fuse 5 2 Failsafe Relay Specifications Maximum Switch...

Страница 55: ...ting Temperature ab 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non con...

Страница 56: ...Technical Specifications 5 5 Dimension Drawings 151 1 199 6 122 7 Figure 5 1 Overall Dimensions RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 47 ...

Страница 57: ... 1 152 4 78 2 50 8 96 5 4 1 50 8 Figure 5 2 Panel and Din Rail Mount Dimensions 19 7 151 4 102 9 113 3 162 5 Figure 5 3 Line Module Dimensions 162 5 40 6 151 8 102 9 113 4 Figure 5 4 Power Module Dimensions 48 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 58: ...Part 1 General Requirements Bi National standard with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives Directive 2014 30 EU Directive 2014 30 EU of the European Parliament and of the Council of 26 F...

Страница 59: ... 16 A per phase and not subject to conditional connection EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standards Immunity for Industrial Environments EN 60825 1 Safety of Laser Products Equipment Classification and Requirements EN 50581 Technical Documentation for the Assessment of Electrical and Electronic Products with Respect to the Restriction of Hazardous Substances EN 5503...

Страница 60: ... U S Food and Drug Administration FDA standard Title 21 Code of Federal Regulations CFR Chapter I Sub chapter J Radiological Health 6 1 5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED Innovation Science and Economic Development Canada standard CAN ICES 3 A NMB 3 A 6 1 6 ANATEL This device meets the regulation for certification and approval of products fo...

Страница 61: ...us substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 9 Other Approvals This device meets the requirements of the following additional standards IEEE 1613 IEEE Standard Envir...

Страница 62: ... to Line 4 Signal ports DC Power Ports AC Power Ports IEC 61000 4 6 Induced Conducted RFI Earth ground ports 10 V 3 100 A m continuous 1000 A m for 1 s Note a IEC 61000 4 8 Magnetic Field Enclosure Ports 1000 A m for 1 s 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 30 for 1 period 60 for 50 periods Signal ports DC Power Ports IEC 61000 4 12 Damped Oscillatory AC Power Ports 2 5 kV c...

Страница 63: ...rts 2 kV DC Power Ports 1 5 kV Dielectric Strength AC Power Ports 2 kV Signal ports 4 kV 2 5 kHz DC Power Ports AC Power Ports Fast Transient Earth ground ports 4 kV Signal ports 2 5 kV common mode 1MHz DC Power Ports Oscillatory AC Power Ports 2 5 kV common 1 kV differential mode 1 MHz Radiated RFI Enclosure ports 35 V m Enclosure Contact 8 kV ESD Enclosure Air 15 kV Environmental Type Tests Test...

Страница 64: ...ertification 6 2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60255 21 3 Seismic Method A Level 2 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 55 ...

Страница 65: ...Certification 6 2 EMC and Environmental Type Tests 56 RUGGEDCOM RX1511 Installation Manual 04 2021 C79000 G8976 1056 20 ...

Страница 66: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: