• Factory setting
Indicates the state of the port on delivery or after reset to factory settings.
• Authentication
Specifies whether the communication partner is authenticated.
• Encryption
Specifies whether or not the transfer is encrypted.
Protocol
Port number
Port status
Factory setting Authentication Encryption
SSH
TCP/22
Open
Open
Yes
Yes
TELNET
TCP/23
Open
(when config‐
ured)
Open
Yes
No
HTTP
TCP/80
Open
(when config‐
ured)
Open
Yes
No
PROFINET IO
Service
TCP/84
Open
Open
No
No
HTTPS
TCP/443
Open
Open
Yes
Yes
DHCP
UDP/68
Open
(when config‐
ured)
Closed
No
No
SNTP
UDP/123
Open
(when config‐
ured)
Closed
No
No
NTP (secure)
Yes
SNMP
UDP/161
Open
(when config‐
ured)
Open
Yes
Yes
(SNMPv3)
PROFINET IO
UDP/34964
UDP/49152,
49153 *
)
Open
Open
No
No
*
)
These ports are assigned dynamically and can differ from the values specified here.
Decommissioning
Shut down the device properly to prevent unauthorized persons from accessing confidential
data in the device memory.
To do this, restore the factory settings on the device.
Also restore the factory settings on the storage medium.
Recommendations on network security
SCALANCE X-200
Operating Instructions, 11/2021, C79000-G8976-C284-15
17
Содержание SIMATIC NET SCALANCE X-200
Страница 8: ...Introduction SCALANCE X 200 8 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 12: ...Safety notices SCALANCE X 200 12 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 18: ...Recommendations on network security SCALANCE X 200 18 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 56: ...Installation and removal 4 9 Disassembly SCALANCE X 200 56 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 80: ...Maintenance and cleaning SCALANCE X 200 80 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 92: ...Technical specifications SCALANCE X 200 92 Operating Instructions 11 2021 C79000 G8976 C284 15 ...
Страница 110: ...Index SCALANCE X 200 110 Operating Instructions 11 2021 C79000 G8976 C284 15 ...