PROFIBUS connection
2.1 Local service
Cloud Connector
Getting Started, 07/2020, C79000-G8976-C507-03
15
The predefined IPv4 rule "Cloud Connector" is enabled for the incoming packets to be
forwarded to the device.
2.1.3
Enabling the TIA Portal Cloud Connector on the PG/PC
Requirement
•
The TIA Portal Cloud Connector V1.1 SP4
https://support.industry.siemens.com/cs/ww/en/view/109764115
) is installed.
You can find additional information on the TIA Portal Cloud Connector in the
documentation "Working with the TIA Portal Cloud Connector
https://support.industry.siemens.com/cs/ww/en/view/109747305
)" and "SIMATIC
Instructions on the TIA Portal Cloud Connector
https://support.industry.siemens.com/cs/ww/en/view/109742490
)".
Activating the TIA Portal Cloud Connector
1.
Start the TIA Portal Cloud Connector.
2.
In the "General" tab, select the "Remote device" option.
3.
Switch to the "Protocol" tab and select the "TCP settings" option.
4.
Configure TCP with the following settings:
Target device
SCALANCE
User device address
IP address of the SCALANCE M804PB
Port
9023
The port must be the same as the port assigned
to the remote device.
5.
To store the settings, click the "Apply" button.
6.
Switch to the "General" tab.
Содержание SIMATIC NET SCALANCE M80PB
Страница 6: ...Preface Cloud Connector 6 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 8: ...Table of contents Cloud Connector 8 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 10: ...Description Cloud Connector 10 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 27: ...PROFIBUS connection 2 2 Remote service Cloud Connector Getting Started 07 2020 C79000 G8976 C507 03 27 ...
Страница 37: ...PROFIBUS connection 2 2 Remote service Cloud Connector Getting Started 07 2020 C79000 G8976 C507 03 37 ...
Страница 38: ......
Страница 60: ...PROFINET connection 3 2 Remote service Cloud Connector 60 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 62: ...Index Cloud Connector 62 Getting Started 07 2020 C79000 G8976 C507 03 ...