Technical Specifications

5

This section provides important technical specifications related to the device.

5.1

Power Supply Specifications

Note

When determining cable lengths, make sure the minimum input voltage for the pow-

er supply is provided at the power source.

Note

Use the internal fuse rating to determine the size of the external circuit breaker/fuse.

Input Range

Power Sup-

ply Type

Min

Max

Internal

Fuse Rating

Maximum

Power Con-

sumption

a

Wire Gage

12 VDC (Single)

10.5 VDC

15 VDC

12 A

77 W

#14 AWG

24 VDC (Single)

13 VDC

36 VDC

10 A

72 W

#14 AWG

48 VDC (Single)

36 VDC

72 VDC

5 A

72 W

#16 AWG

88 VDC

300 VDC

77 W/ 76W

High Volt-

age AC/DC

85 VAC

b

264 VAC

b

3.15 A

75 W/ 75W

#16 AWG

a

Based on nominal input voltages and 60W output load.

b

Rated at frequency range 47Hz - 63Hz.

5.2

PoE Power Supply Specifications

The RUGGEDCOM RST2228P adheres to the following power output and IEEE specifi-

cations depending on the input voltage supplied to the device.

CAUTION

Electrical hazard — risk of damage to the device. Do not connect or disconnect the

POE power terminal block when the POE power source is on.

Power In

Voltage Range

Internal

Fuse Rating

Power Out

Wire Gage

a

51-57 VDC

12 A Maximum

50-57 VDC, 60 W per Port

Maximum (IEEE 302.at)

#18-#12 AWG

RUGGEDCOM RST2228P

Installation Manual, 12/2019, C79000-G8976-1403-05

35

Содержание SIMATIC NET RUGGEDCOM RST2228

Страница 1: ...Edition 12 2019 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RST2228P For RST2228 https www siemens com ...

Страница 2: ...rnet Switches RUGGEDCOM RST2228P Installation Manual For RST2228 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 12 2019 C79000 G8976 1403 05 ...

Страница 3: ... personnel are those who based on their training and experience are capable of identify ing risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufactur...

Страница 4: ... Fiber Optic Cables 8 2 Installing the Device 9 2 1 General Procedure 9 2 2 Unpacking the Device 10 2 3 Mounting the Device 10 2 3 1 Mounting the Device to a Rack 11 2 3 2 Mounting the Device to a Panel 12 2 4 Connecting the Failsafe Alarm Relay 13 2 5 Connecting Power 15 2 5 1 Connecting High AC DC Power 15 2 5 2 Connecting Low DC Power 18 2 5 3 Connecting External PoE Power 20 2 5 4 Wiring Examp...

Страница 5: ...ons 36 5 4 Supported Networking Standards 36 5 5 Operating Environment 36 5 6 Mechanical Specifications 37 5 7 Dimension Drawings 37 6 Certification 41 6 1 Approvals 41 6 1 1 CSA 41 6 1 2 European Union EU 41 6 1 3 FCC 42 6 1 4 FDA CDRH 43 6 1 5 ISED 43 6 1 6 TÜV SÜD 43 6 1 7 RoHS 43 6 1 8 Other Approvals 44 6 2 EMC and Environmental Type Tests 44 iv RUGGEDCOM RST2228P Installation Manual 12 2019 ...

Страница 6: ...ser documentation for RUGGEDCOM RST2228P is available online at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Disclaimer of Liability Siemens has verified the contents of this document against the hardware and or soft ware described However deviations between the product and the documentation may exist Siemens shall not be liable fo...

Страница 7: ...n about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical support or general information contact Siemens Customer Support through any of the following methods Online Visit http www siemens com automation support request to submi...

Страница 8: ...ry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 10: ...COM RST2228P which provides advanced Layer 2 networking functions and advanced cyber security fea tures 1 1 Feature Highlights Power over Ethernet PoE Supports up to 24 PoE ports with data transfer rates of 10 100 1000 Mbit s Supports 4 pair or 60 W port Supports up to 120 W of PoE power module e g two 60 W ports or four 30 W ports Supports up to maximum 500 W system Data and power over a single E...

Страница 11: ...s able to detect loss of input voltage Reliability in Harsh Environments Immunity to EMI and heavy electrical surges Zero Packet Loss Technology Supports Siemens FastConnect RJ45 Cabling System 40 to 85 C 40 to 185 F operating temperature fan less Conformal coated printed circuit boards optional 1 2 Description The RUGGEDCOM RST2228P features various ports controls and indicator LEDs for connectin...

Страница 12: ...t are located on the front panel 9 2 1 3 4 5 6 7 8 1 Status Panel 2 ACO Button 3 CLP Port 4 USB Console Port 5 PoE Power and Failsafe Alarm Relay Terminal Block 6 Power Terminal Block 7 SFP SFP Transceiver Sockets 8 Media Modules 9 Chassis Ground Terminal Figure 1 1 RUGGEDCOM RST2228P Front Panel Orientation RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 3 ...

Страница 13: ...r Sockets 8 Media Modules 9 Chassis Ground Terminal Figure 1 2 RUGGEDCOM RST2228P Rear Panel Orientation Key Features Status Panel The status panel displays the real time status of the device Six module slot locators indicate the physical location of each media module in relation to the available chassis slots Module ports are numbered from left to right when installed in the chassis A dedicat ed ...

Страница 14: ...e Solid The PoE power source is supplying power to the device PoE Off The PoE power source is not supplying power to the device USB Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about con necting to the device via the serial console port refer to Connect ing to the Device Page 25 Alarm Indicator LED The a...

Страница 15: ...he proper wire gage refer to Power Supply Specifications Page 35 Lightning protector For protecting the device from harmful electrical strikes Flathead screwdriver For removing or installing modules and terminal blocks Torx T10 screwdriver For removing or installing modules Phillips screwdriver For removing or installing terminal blocks 8 x M6 or 10 32 screws For mounting the device to a panel 8 x...

Страница 16: ...d potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gigabit Ethernet standard defines 1000 Mbit s Ethernet commu nications over distances of up to 100 m 328 ft using all 4 pairs in category 5 or higher balanced unshielded twisted pair cabling For wiring guidelines system de signers and integrato...

Страница 17: ...90 angles when necessary to reduce inductive coupling Shielded screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Band width MHz km 100Base FX 1000Base SX 10GBase SR 850 ...

Страница 18: ...tempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment NOTICE This product should be installed in a restricted access location where access can only be gained by authorized personnel who h...

Страница 19: ...mation refer to Connecting the Failsafe Alarm Relay Page 13 6 Connect power to the device and ground the device to safety Earth For more information refer to Connecting Power Page 15 7 Connect the device to the network For more information refer to Communication Ports Page 29 8 Configure the device For more information refer to Configuring the Device Page 26 2 2 Unpacking the Device When unpacking...

Страница 20: ...rack or panel hardware installed refer to Dimension Drawings Page 37 2 3 1 Mounting the Device to a Rack The RUGGEDCOM RST2228P can be secured to a standard 48 cm 19 in rack using separately purchased rack mount adapters The adapters can be installed at the front or rear of the chassis Each adapter kit includes four adapters To secure the device to a rack do the following 1 Secure the mounting ada...

Страница 21: ... airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space 3 Secure the adapters to the rack using M6 or 10 32 screws 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RST2228P can be ordered with panel adapters for each side of the chassis The a...

Страница 22: ...e NO Normally Open contact is closed when the unit is powered and there are no ac tive alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RST2228P One common application for this relay is to signal an alarm if a power failure occu...

Страница 23: ... device when the safety cover is in stalled later in the installation process For a pluggable terminal block insert the terminal block into the device and tighten the screws 1 2 1 Pluggable Terminal Block 2 Screw Type Terminal Block Figure 2 4 Assembling the Failsafe Alarm Relay Terminal Block 2 Connect a failsafe device to the terminal block 5 1 4 4 5 3 2 3 1 Pluggable Terminal Block 2 Screw Type...

Страница 24: ...d risk of damage to equipment Do not exceed the power supply voltage ratings for each power supply input For example if PS1 is a low DC power supply do not connect the PS1 terminals to a high AC DC power source NOTICE A circuit breaker rated no higher than 20 A must be installed between the device and the supply mains Whenever possible use a separate circuit breaker for each power supply For maxim...

Страница 25: ...is installed using Phillips screws and compression plates allowing either bare wire connections or crimped terminal lugs Use 6 size ring lugs for secure reliable screws which must be removed to make connections 1 Connect the power supply terminal block to the device 1 2 1 Pluggable Terminal Block 2 Screw Type Terminal Block Figure 2 6 Assembling the Power Supply Terminal Block 16 RUGGEDCOM RST2228...

Страница 26: ...tral N Terminal for PS1 6 Positive Line L Terminal for PS2 7 Chassis Ground Terminal for PS2 8 Negative Neutral N Terminal for PS2 Figure 2 7 AC Terminal Block Wiring 3 Connect the ground wire to the chassis ground terminal on the terminal block 4 Connect the Neutral wire from the power source to the negative neutral N terminal on the terminal block 5 For screw type terminal blocks install the saf...

Страница 27: ...Note The screw type terminal block is installed using Phillips screws and compression plates allowing either bare wire connections or crimped terminal lugs Use 6 size ring lugs for secure reliable screws which must be removed to make connections CAUTION Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power ...

Страница 28: ...inal on the terminal block 1 2 3 4 5 3 4 5 7 8 6 6 7 8 1 Pluggable Terminal Block 2 Screw Type Terminal Block 3 Positive Terminal for PS1 4 Chassis Ground Terminal for PS1 5 Negative Terminal for PS1 6 Positive Terminal for PS2 7 Chassis Ground Terminal for PS2 8 Negative Terminal for PS2 Figure 2 11 DC Terminal Block Wiring 3 Connect the negative wire from the power source to the negative termina...

Страница 29: ...s Ground Connection 2 5 3 Connecting External PoE Power The RUGGEDCOM RST2228P supports up to twenty four 10 100 1000 Mbps Pow er over Ethernet PoE ports that require external power DANGER Electrocution hazard risk of serious personal injury The PoE power supply is in tended to have a local connection to a PoE DC output power supply Make sure the PoE power supply has galvanic isolation from high v...

Страница 30: ...pecification 15 W port output the external power supply must meet the following requirements Input Range Power Sup ply Type Minimum Maximum Isolation Minimum Pow er Required DC 45 VDC 57 VDC 1 5 kVAC 2 2 kVDC 72 W a a Based on a single 4 port module To connect an external power supply for the PoE ports do the following 1 Secure a European style terminal block or Euroblock to the terminal 1 2 3 4 3...

Страница 31: ...iring Examples The following illustrate how to connect single and dual power supplies to the device Figure 2 15 Single High AC DC Power Supply Figure 2 16 Single Low DC Power Supply 22 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 32: ...Installing the Device 2 5 4 Wiring Examples Figure 2 17 Dual High AC DC Power Supply Figure 2 18 Dual Low DC Power Supply RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 23 ...

Страница 33: ...nstalling the Device 2 5 4 Wiring Examples Figure 2 19 High AC DC Power Supply and Low DC Power Supply Figure 2 20 PoE Power Supply 24 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 34: ...d only as a temporary connection during initial configuration or troubleshooting Note For Microsoft Windows users the RUGGEDCOM USB Serial Console driver must be in stalled on the users workstation before connecting via the USB Type B console port For more information refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RST2228P Use the following settings to connect to the port Speed ...

Страница 35: ...when the CLP is not in use CAUTION Mechanical electrical hazard risk of damage to the CLP Do not expose the CLP to extreme temperatures or humidity Do not expose the CLP to large magnetic or static electric fields Do not bend or drop the CLP CAUTION Security hazard risk of unauthorized access and or exploitation Make sure to remove the CLP before decommissioning the device or sending the de vice t...

Страница 36: ...lat head screwdriver into the bottom portion of the CLP port and gently pry the CLP out 1 2 1 CLP 2 Protective cover Figure 3 1 Removing the CLP 2 Insert the protective cover or a new CLP to prevent the ingress of dust and dirt RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 27 ...

Страница 37: ...ng the CLP To install the CLP do the following 1 Remove the protective cover from the CLP port 1 2 1 Protective cover 2 CLP Figure 3 2 Installing the CLP 2 Insert the CLP into the CLP port 28 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 38: ...upported Modules can be installed in any one of the available slots in the device chassis Mod ule slot locations and port status are indicated on the status panel For more informa tion about the status panel refer to Description Page 2 Use RUGGEDCOM RST2228P to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROS Configuration Manual for the device 0 1 2...

Страница 39: ...peed Mbit s Mode a Nominal Distance km RUGGEDCOM SFP1112 1 6GK6000 8CG01 0AA0 10 100 1000 0 1 RUGGEDCOM SFP1121 1FX2A b 6GK6000 8FE50 0AA0 100 MM 2 RUGGEDCOM SFP1121 1FX2 c 6GK6000 8FE51 0AA0 100 MM 2 RUGGEDCOM SFP1131 1FX20 c 6GK6000 8FE52 0AA0 100 SM 20 RUGGEDCOM SFP1131 1FX50 c 6GK6000 8FE53 0AA0 100 SM 50 RUGGEDCOM SFP1131 1FX90 c 6GK6000 8FE54 0AA0 100 SM 90 RUGGEDCOM SFP1122 1SX 6GK6000 8FG5...

Страница 40: ... power schedule to conserve power For more information refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RST2228P For information about connecting the external power supply refer to Connecting External PoE Power Page 20 LEDs Each port features an LED to indicates the state of the port State Description Green Solid Link detected Yellow Solid Link detected and PoE established Blinkin...

Страница 41: ...K6297 2SA00 4AA1 Conformal Coated RUGGEDCOM RMM2942 4LC2 Specifications Ports 4 Port Type LC Mode MM Mul ti Mode Speed 100 Mbps Interface FX Wavelength 1310 nm Distance 2 km 1 2 mi Article Numbers 6GK6294 2LD00 4AC0 Standard 6GK6294 2LD00 4AC1 Conformal Coated PoE Modules RUGGEDCOM RMM2973 4POE P P Specifications Ports 4 Port Type RJ45 Power per Port 60 W Power per Module 120 W Speed 10 100 1000 M...

Страница 42: ...ssociated with the module are available in RUGGEDCOM RST2228P For more information refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RST2228P Once a media module is removed all the features associated with the module are hidden or disabled in RUGGEDCOM RST2228P CAUTION Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that may lead to...

Страница 43: ...ct power to the device Installing a Module To install a media module do the following 1 Make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate 2 Optional If the device is installed in a rack remove it from the rack 3 Remove the current module from the slot 4 Insert the new module into the slot Figure 4 3 Installing a Module 5 Ti...

Страница 44: ...VDC Single 36 VDC 72 VDC 5 A 72 W 16 AWG 88 VDC 300 VDC 77 W 76W High Volt age AC DC 85 VAC b 264 VAC b 3 15 A 75 W 75W 16 AWG a Based on nominal input voltages and 60W output load b Rated at frequency range 47Hz 63Hz 5 2 PoE Power Supply Specifications The RUGGEDCOM RST2228P adheres to the following power output and IEEE specifi cations depending on the input voltage supplied to the device CAUTIO...

Страница 45: ... 125 VDC 0 15 A 1 5kVAC 150 VAC 2 A 1 5kVAC 5 4 Supported Networking Standards Parameter 10 Mbps 100 Mbps 1000 Mbps 10000 Mbps Notes IEEE 802 1AB ü ü ü ü Link Layer Discov ery Protocol LLDP IEEE 802 1D ü ü ü ü MAC bridges IEEE 802 1Q ü ü ü ü VLAN Virtual LAN IEEE 802 1p ü ü ü ü Priority levels IEEE 802 1x ü ü ü ü Port based net work access control IEEE 802 3 ü 10Base T IEEE 802 3u ü 100Base TX 100...

Страница 46: ...us surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 6 Mechanical Specifications Weight 8 0 kg 18 lbs Ingress Protection IP40 Enclosure Galvanized steel 5 7 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated ...

Страница 47: ...Technical Specifications 5 7 Dimension Drawings 339 4 43 6 337 0 446 0 22 5 Figure 5 1 Overall Dimensions 38 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 48: ... 462 2 31 6 23 5 314 0 43 6 285 2 23 5 11 8 297 0 273 5 Figure 5 2 Rack Mount Dimensions 3 5 6 8 462 2 31 6 23 5 43 6 285 2 23 5 11 8 297 0 273 5 314 0 Figure 5 3 Panel Mount Dimensions RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 39 ...

Страница 49: ...Technical Specifications 5 7 Dimension Drawings 40 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 50: ...Association CSA standards under certificate 16 70068356 CAN CSA C22 2 No 60950 1 Information Technology Equipment Safety Part 1 General Requirements Bi National Standard with UL 60950 1 UL 60950 1 Information Technology Equipment Safety Part 1 General Requirements The device is marked with a CSA symbol that indicates compliance with both Canadi an and U S requirements C US 6 1 2 European Union EU ...

Страница 51: ... with Respect to the Restriction of Hazardous Substances The device is marked with a CE marking and can be used throughout the European community A copy of the CE Declaration of Conformity is available from Siemens AG For contact information refer to Contacting Siemens Page vii 6 1 3 FCC This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 1...

Страница 52: ...CES 3 A NMB 3 A 6 1 6 TÜV SÜD This device is certified by TÜV SÜD to meet the requirements of the following stan dards CSA EN IEC UL 60950 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 7 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro HS Restriction of Hazardous Substances directives for the restricted use of certain hazardous sub...

Страница 53: ...r IEC 61850 3 Note In the case of an all fiber port configuration this product meets all Class 2 re quirements Otherwise all Class 1 requirements are met for copper ports If the unit contains copper ports the IEC 1613 conformance is Class 1 during which disturbance errors may occur but recovery is automatic If the unit contains all fiber ports the IEC1613 conformance is Class 2 during which no dis...

Страница 54: ...s 5 IEC 61000 4 10 Damped Oscillat ing Magnetic Field Enclosure Ports 100 A m for 1 s 100 kHz and 1 MHz 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 30 for 1 period 60 for 50 periods 100 for 5 periods 100 for 50 periods Signal Ports 30 V for 60 s 300 V for 1 s 4 DC Power Ports 30 V for 60 s 300 V for 1 s 4 IEC 61000 4 16 Mains Frequen cy Voltage AC Power Ports 30 V for 60 s 300 V fo...

Страница 55: ...diated RFI Enclosure Ports 35 V m 80 modulation Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Fast Transient Earth Ground Ports 4 kV Signal Ports 2 5 kV common mode DC Power Ports 2 5 kV common and 1 0 kV Differential Mode Oscillatory AC Power Ports 2 5 kV common and 1 0 kV Differential Mode Signal Ports 5 kV Failsafe Relay DC Power Ports 5 kV HV Impulse AC Power Ports 5 kV Sig...

Страница 56: ...tem perature 97 low er temperature 55 C 131 F 6 Cycles IEC 60068 2 78 Humidity Damp Heat Steady State Test Cab 10 days 55 C 131 F and 93 Relative Humidity IEC 60255 21 1 Vibration Level 2 2 g 10 to 150 Hz Class 2 Shock Level 2 30 g 11 mS Class 2 IEC 60255 21 2 Bump Level 1 10 g 16 mS Class 1 IEC 60255 21 3 Seismic Method A Class 2 Class 2 IEC 60529 Ingress Protection IP4x IEC 60068 2 31 Free Fall ...

Страница 57: ...Certification 6 2 EMC and Environmental Type Tests 48 RUGGEDCOM RST2228P Installation Manual 12 2019 C79000 G8976 1403 05 ...

Страница 58: ...ttps www siemens com Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: