Modules
4.3 Installing/Removing Power Supply Modules
Installing a Line Module
To install a line module, do the following:
1. For Control and switch modules only, make sure power to the device has been
disconnected and wait approximately two minutes for any remaining energy to
dissipate.
2. [Optional] If the device is installed in a rack, remove it from the rack.
3. Remove the current module from the slot.
4. Insert the new module into the slot.
1
2
3
1
Chassis
2
Module
3
Screw
Figure 4.4
Installing a Module
5. Tighten the screws to secure the module.
6. [Optional] If necessary, install the device in the rack.
7. For control and switch modules only, connect power to the device.
4.3
Installing/Removing Power Supply Modules
The RUGGEDCOM MX5000 supports dual redundant power supplies that can be
installed in any combination.
30
RUGGEDCOM MX5000
Installation Manual, 01/2021, C79000-G8976-1059-13