Introduction

1.3 Required Tools and Materials

Mode

Color/State

Description

Green (Blinking)

1000 Mbps

Orange (Solid)

10 Mbps

Off

No link detected

Display Mode Indicator LEDs

The display mode indicator LEDs indicate the current display mode

for the port status indicator LEDs (i.e. Status, Duplex or Speed).

Mode Button

The 

Mode

 button sets the display mode for the port status indicator

LEDs (i.e. Status, Duplex or Speed). It can also be used to reset the

device if held for 5 seconds.

Alarm Indicator LED

The alarm indicator LED illuminates when an alarm condition exists.

Power Module Indicator LEDs

The power module indicator LEDs indicate the status of the power

modules.

Green

 – The power supply is supplying power

Red

 – Power supply failure

Off

 – No power supply is installed

RS-232 Console Port

The serial console port is for interfacing directly with the device

and accessing initial management functions. For information

about connecting to the device via the serial console port, refer to

"Connecting to the Device (Page 21)"

.

1.3

Required Tools and Materials

The following tools and materials are required to install the RUGGEDCOM M2100:

Tools/Materials

Purpose

AC power cord (16 AWG)

For connecting power to the device.

CAT-5 Ethernet cables

For connecting the device to the network.

Flathead screwdriver

For mounting the device to a DIN rail.

Phillips screwdriver

For mounting the device to a panel.

4 x #8-32 screws

For mounting the device to a panel.

1.4

Decommissioning and Disposal

Proper decommissioning and disposal of this device is important to prevent malicious

users from obtaining proprietary information and to protect the environment.

Decommissioning

This device may include sensitive, proprietary data. Before taking the device out of

service, either permanently or for maintenance by a third-party, make sure it has

been fully decommissioned.
For more information, refer to the associated 

Configuration Manual

.

RUGGEDCOM M2100

Installation Manual, 04/2021, C79000-G8976-1042-17

3

Содержание SIMATIC NET RUGGEDCOM M2100

Страница 1: ...Edition 04 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M2100 https www siemens com ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM M2100 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2021 C79000 G8976 1042 17 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...ported Fiber Optic Cables 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 9 2 3 Mounting the Device 9 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 12 2 5 Connecting Power 13 2 5 1 Connecting AC or DC Power 14 2 5 2 Wiring Examples 16 3 Device Management 21 3 1 Connecting to the Device 21 3 2 Confi...

Страница 5: ...tions 29 5 6 Operating Environment 30 5 7 Mechanical Specifications 30 5 8 Dimension Drawings 30 6 Certification 35 6 1 Approvals 35 6 1 1 CSA 35 6 1 2 European Union EU 35 6 1 3 FCC 36 6 1 4 FDA CDRH 36 6 1 5 ISED 36 6 1 6 ISO 37 6 1 7 RoHS 37 6 1 8 Other Approvals 37 6 2 EMC and Environmental Type Tests 37 iv RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 6: ...rt Registered Trademarks RUGGEDCOM ROS RCDP and RUGGEDCOM Discovery Protocol are registered trademarks of Siemens Canada Ltd Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years from the date of purchase conditional upon the return to factory...

Страница 7: ...ucture technologies Siemens unique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer sup...

Страница 8: ...emens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 10: ...ort multiple fiber connectors ST MTRJ LC SC without loss of port density The RUGGEDCOM M2100 is packaged in a rugged galvanized steel enclosure with industrial grade DIN panel or 48 cm 19 in rack mount mounting options 1 1 Feature Highlights Ethernet Ports Up to 3 x Gigabit Ethernet ports copper and fiber Up to 16 x 100Base FX Fiber Fast Ethernet ports 2 port modules for tremendous flexibility Non...

Страница 11: ...r or Copper Ethernet Ports 2 Port Status Indicator LEDs 3 Mode Button 4 RS 232 Serial Console Port RJ45 5 Display Mode Indicator LEDs 6 Alarm Indicator LED 7 Power Module Indicator LEDs Figure 1 1 RUGGEDCOM M2100 Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM M2100 operating system are described in Communication Ports Page 23 Port Status Indicator LEDs Po...

Страница 12: ...t functions For information about connecting to the device via the serial console port refer to Connecting to the Device Page 21 1 3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM M2100 Tools Materials Purpose AC power cord 16 AWG For connecting power to the device CAT 5 Ethernet cables For connecting the device to the network Flathead screwdri...

Страница 13: ...ground potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gigabit Ethernet standard defines 1000 Mbit s Ethernet communications over distances of up to 100 m 328 ft using all 4 pairs in category 5 or higher balanced unshielded twisted pair cabling For wiring guidelines system designers and integr...

Страница 14: ... 90 angles when necessary to reduce inductive coupling Shielded screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 ...

Страница 15: ...Introduction 1 5 3 Supported Fiber Optic Cables 6 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 16: ... radiation exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null an...

Страница 17: ... 1 in of space is required between units A pollution degree of 2 is required The failsafe relay connection must be from a certified Safey Extra Low Voltage SELV source isolated from the mains supply Rack mount installations must be performed by trained certified personnel in accordance to the installation instructions and local electrical code 2 1 General Procedure The general procedure for instal...

Страница 18: ...sure As such it is recommended that 2 5 cm 1 in of space be maintained on all open sides of the device to allow for some convectional airflow For CSA compliant installations a minimum forced airflow of 0 27 m s at 400 CFM is required Note that any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space N...

Страница 19: ...ant installations a minimum forced airflow of 0 27 m s at 400 CFM is required Note that any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Do not exceed the maximum number of devices or weight restrictions specified by the rack manufacturer Do not overload the supply circuit Refer to the over cu...

Страница 20: ...adapters to be installed up to 25 mm 1 in from the face of the device 1 2 3 3 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required install adapters on the opposite side of the device to protect from vibrations 3 Insert the device into the rack 4 Secure the adapters to the rack using the supplied hardware 2 3 2 Mounting the Device to a Panel For panel installations the R...

Страница 21: ...rm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM M2100 One common application for this relay is to signal an alarm if a power ...

Страница 22: ... connections under severe shock or vibration NOTICE Electrical hazard risk of damage to the device Make sure power input to the device is within the specified input range For information about the nominal input range for the device refer to Power Supply Specifications Page 27 Note For maximum redundancy in a dual power supply configuration use two independent power sources Use minimum 16 gage copp...

Страница 23: ...o avoid damage to transient suppression circuitry during testing NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 24 or 48 VDC power supply Damage to the power supply may occur IMPORTANT Each internal power module is labeled POWER 1 or POWER 2 Make sure to connect the power supply to the corresponding internal power module 1 Remove the terminal block cover 2...

Страница 24: ...d Terminal 7 Chassis Ground Terminal 8 Chassis Ground Connection Figure 2 4 Terminal Block Wiring 5 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 6 Install the supplied metal jumper between terminals 2 4 and 6 to connect the surge ground terminals to the chassis ground terminal The surge ground terminals are used as the ground conductor fo...

Страница 25: ... 2 6 32 Screw 3 6 Ring Lug Figure 2 5 Chassis Ground Connection DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied terminal block cover is always installed before the device is powered 8 Install the terminal block cover 2 5 2 Wiring Examples The following illustrate how to connect power to single and dual power supplies 16 RUGGEDCOM...

Страница 26: ...Installing the Device 2 5 2 Wiring Examples Figure 2 6 Single AC Power Supply Figure 2 7 Single DC Power Supply RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 17 ...

Страница 27: ...Installing the Device 2 5 2 Wiring Examples Figure 2 8 Dual AC Power Supply Figure 2 9 Dual DC Power Supply 18 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 28: ...Installing the Device 2 5 2 Wiring Examples Figure 2 10 Dual AC DC Power Supply RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 19 ...

Страница 29: ...Installing the Device 2 5 2 Wiring Examples 20 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 30: ... to RUGGEDCOM M2100 s console and Web interfaces NOTICE The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Description C...

Страница 31: ...ch and access the RUGGEDCOM M2100 console and Web interfaces via the device s IP address For more information about available ports refer to Communication Ports Page 23 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM M2100 interface For more information about configuring the device ref...

Страница 32: ...t any combination of fiber or copper Ethernet connectors up to 100 Mbps The exact configuration of the device can be determined by reading the factory data file through the RUGGEDCOM M2100 user interface For more information about how to read the factory data file refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM M2100 Port LEDs Each communication port is equipped with an LED that ...

Страница 33: ...ice and can accept CAT 5 shielded twisted pair STP cables Pin Out The following is the pin out description for the Micro D connectors 1 6 Figure 4 3 Micro D 10 100 1000Base TX Port Pin Configuration Pin 10 100Base TX 1000Base TX 1 RX A 2 Reserved Do Not Connect C 3 Reserved Do Not Connect 4 Reserved Do Not Connect D 5 TX B 6 RX A 7 Reserved Do Not Connect C 8 Reserved Do Not Connect D 9 TX B Speci...

Страница 34: ...eive Rx connections of each port are properly connected and matched to establish a proper link 2 1 1 Tx Connector 2 Rx Connector Figure 4 4 MTRJ Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 5 LC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 6 SC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 7 ST Port For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Etherne...

Страница 35: ...Communication Ports 4 2 Fiber Optic Ethernet Ports 26 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 36: ...125 250 VDC d 88 VDC 300 VDC 2 A T HI 110 230 VAC d 85 VAC 264 VAC 2 A T 28 W a F denotes fast acting fuse b T denotes time delay fuse c Power consumption varies based on configuration 10 100Base TX ports consume roughly 1 W less than fiber optic ports d The HI power supply is the same power supply for both AC and DC 5 2 Failsafe Relay Specifications Maximum Switching Voltage 250 VAC 125 VDC Rated...

Страница 37: ...lowing details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM M2100 Note Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances All optical power numbers are listed as dBm averages F51 transceivers are rated for 40 to 85 C 40 ...

Страница 38: ... 16 5 10 6 34 11 2 2 21 MM ST 50 125 1310 15 7 15 7 33 5 11 2 17 SM ST 9 125 1310 27 14 35 3 5 8 MM LC 50 125 1310 19 14 32 14 2 15 SM LC 9 125 1310 15 8 32 7 20 16 5 SM LC 9 125 1310 5 0 35 3 50 32 5 SM LC 9 125 1310 5 5 37 0 90 39 5 a Typical b Typical distance The maximum distance is greatly dependent on factors such as cable type the number of connectors and number of splices Consult a Siemens...

Страница 39: ...mperature a 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity b 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Non condensing 5 7 Mechanical Specifications Weight 5 2 kg 11 5 lbs Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel 5 8 Dimension Drawings Note All dimension...

Страница 40: ...Technical Specifications 5 8 Dimension Drawings 285 49 438 15 44 45 313 18 0 8 Figure 5 1 Overall Dimensions RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 31 ...

Страница 41: ...ions 5 8 Dimension Drawings 479 29 314 7 308 10 28 96 51 05 25 40 11 68 32 77 461 0 6 35 31 75 9 9 6 35 470 4 21 08 12 70 Figure 5 2 Rack Mount Dimensions 32 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 42: ...fications 5 8 Dimension Drawings 44 5 368 0 325 6 309 6 293 4 259 1 86 4 172 7 11 4 23 4 7 4 467 4 275 6 51 3 482 6 Figure 5 3 Panel Mount Dimensions RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 33 ...

Страница 43: ...Technical Specifications 5 8 Dimension Drawings 34 RUGGEDCOM M2100 Installation Manual 04 2021 C79000 G8976 1042 17 ...

Страница 44: ...UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standa...

Страница 45: ... energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense NOTICE Changes or modifications not expressly approved by the party responsible for compl...

Страница 46: ...c Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 8 Other Approvals This device meets the requirements of the following additional standards IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations IEC 61000 6 2 Electromagnetic Comp...

Страница 47: ...te a DC Power Ports AC Power Ports IEC 61000 4 4 Burst Fast Transient Earth Ground Ports 4 kV 4 Signal Ports 4 kV Line to Ground 2 kV Line to Line 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Surge AC Power Ports 4 kV Line to Ground 2 kV Line to Line 4 Signal Ports DC Power Ports AC Power Ports IEC 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 100 A m Continuo...

Страница 48: ...lass 2 requirements for an all fiber configuration and Class 1 requirements for copper ports Class 1 allows for temporary communication loss while Class 2 requires error free and interrupted communications Description Test Levels Enclosure Contact 2 kV 4 kV 8 kV ESD Enclosure Air 4 kV 8 kV 15 kV Radiated RFI Enclosure Ports 35 V m Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV F...

Страница 49: ...ilitary Standard Tests Test Description Test Levels MIL STD 901D Shock Hard Mounted Grade A Equipment Class I Shock Type A Equipment MIL STD 167 1 Vibration Type I 4 33 Hz MIL STD 461E Electromagnetic Interference CE101 CE102 CS101 CS114 CS115 CS116 RE101 RE102 RS101 RS103 MIL STD 1399 Magnetic Field DC Magnetic Exposure Section 070 Part 1 MIL STD 810F Low Pressure Altitude Storage Low Pressure Al...

Страница 50: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: