Detailed descriptions
16.2 Bus boards
SIMATIC IPC647C
Operating Instructions, 12/2010, A5E02669337-02
169
16.2.2
Exclusive PCI hardware interrupt
Applications demanding high-performance interrupt handling require high-speed hardware
interrupt reaction. The PCI hardware interrupt should only be used by one resource in order
to ensure high-speed reaction of the hardware.
Setting up an exclusive interrupt on the device (only APIC mode)
An exclusive interrupt can only be used for PCI slot 2 and slot 3. Further exclusive interrupts
for use at the slots are not available.
Assigning exclusive interrupts in BIOS Setup (PIC mode only)
The interrupts are automatically assigned to the slots at system startup due to the default
settings in system BIOS.
Several slots may share the same interrupt, depending on the system configuration. This
functionality is known as interrupt sharing. Exclusive interrupts are not available in PIC
mode. Disable specific system resources in order to obtain exclusive interrupts. The resulting
free interrupt is then assigned to the slots. The lower free IRQ is assigned to the lower Slot
No.
If a conflict arises through the assignment, a message will be displayed and has to be
acknowledged.
Message: "Resources Conflict. Please re-select [ok]"
The interface that causes the conflict is disabled automatically. Additional information is
available in the section
8
If you want to use "IRQ 3" for a slot, you have to disable the "Internal COM 2" by using
Advanced > Peripheral Configuration. IRQ 3 is then assigned automatically to the slot that
has the lowest slot number.
IRQ assignments for Windows (APIC mode)
Ethernet 1
16
1) 2)
Ethernet 2
17
1)
PROFIBUS/MPI
19
1)
PCI slot 1
20
1)
PCI slot 2
21
1)
PCI Express slot
16
1) 3)
1)
Requirement: The modules in the PCI slots each require only one interrupt
2)
Requirement: VGA and PCI Express do not require an interrupt
3)
Requirement: VGA does not require an interrupt and Ethernet1 is disabled
Содержание Simatic IPC647C
Страница 12: ...Safety notes 2 1 General safety instructions SIMATIC IPC647C 12 Operating Instructions 12 2010 A5E02669337 02 ...
Страница 30: ...Application planning 4 4 Access protection SIMATIC IPC647C 30 Operating Instructions 12 2010 A5E02669337 02 ...
Страница 122: ......
Страница 146: ......
Страница 246: ...Index SIMATIC IPC647C 246 Operating Instructions 12 2010 A5E02669337 02 ...