Transponder
7.6 MDS D127
SIMATIC RF200
204
System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.6
MDS D127
7.6.1
Features
MDS D127
Characteristics
Area of application
Very compact data carrier that can be screwed into
areas where precise positioning is necessary;
e.g. tool identification, workpiece holders etc.
Memory size
112 bytes of EEPROM user memory
Write/read range
See section "Field data (Page 37)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
7.6.2
Ordering data
Table 7- 13 Ordering data for MDS D127
Article number
MDS D127
Pack of 10
(A screw-in aid is supplied with each pack)
6GT2600-0AF00