Appendix
A.2 Accessories
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
317
A.2.2.7
Parameterization
Parameter settings can be performed using the tool "RF290R-Set" (V9.5.2).
This tool is primarily used for parameterization and commissioning, and is not designed for
productive operation.
The relevant parameters of the RF260X can be set in the "Configuration" menu under
"SystemParameters > CFG15: Antenna Multiplexing"
①
Figure A-3 Menu "Configuration" MOBYDSet"
●
For operation with RF260X, you need to activate the "Multiplexing" function
②
.
●
The number of occupied channels must be specified under "Number of Output Channels"
②
.
●
In "Multiplexer Valid Times"
③
, the maximum time available for the antenna to read a
transponder is entered. Following this time, the device switches to the next antenna
automatically. If the read was successful, the time may be significantly shorter than
specified here.
Содержание SIMATIC Ident
Страница 1: ......
Страница 2: ......
Страница 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 88: ...RF200 system planning 4 4 Further information SIMATIC RF200 88 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 352: ...Appendix A 5 Service Support SIMATIC RF200 352 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 362: ......