Transponder
7.11 MDS D261
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
227
7.10.5
Dimension drawing
Dimensions in mm
Figure 7-22 Dimension drawing of MDS D200
7.11
MDS D261
7.11.1
Features
MDS D261
Characteristics
Area of application
The design of the transponder (self-adhesive label)
permits a variety of designs, guaranteeing optimum
dimensioning for the widest variety of applications.
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identifi-
cation.
Memory size
256 bytes of EEPROM user memory
Write/read range
See section Field data (Page 37).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP65
7.11.2
Ordering data
Table 7- 26 Ordering data for MDS D261
Article number
MDS D261
6GT2600-1AA00-0AX0
Содержание SIMATIC Ident
Страница 1: ......
Страница 2: ......
Страница 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 88: ...RF200 system planning 4 4 Further information SIMATIC RF200 88 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 352: ...Appendix A 5 Service Support SIMATIC RF200 352 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Страница 362: ......