Operator controls and displays
5.5 Operator controls
Mobile Panel 277F IWLAN
108
Operating Instructions, 12/2007, A5E01003940-01
%XWWRQELWV
/('ELWV
%\WH
) ) ) ) ) ) ) )
) ) ) ) ) ) ) )
) )
7 7
) ) ) ) ) ) ) )
) ) ) ) ) )
) )
) )
7
7 6 6
,
,
,
,
,
,
,
,
' ' ' ' ' ' ' '
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
F
Bit for function key
S
Bit for key-operated switch
T1
Bit for left illuminated pushbutton
T2
Bit for right illuminated pushbutton
I
Bit for handwheel pulses, forwards
D
Bit for handwheel pulses, backwards
The bytes "n+6" to "n+9" contain the direct key bits for the touch buttons.
Bit coding
The following tables show the bit coding for function keys, key-operated switch, illuminated
pushbutton and handwheel:
● Bit coding of function keys
State
F1 to F18
Not pressed
0
Pressed
1
● Bit coding of function key LEDs
State
F1 to F18
LED not illuminated
0
LED is illuminated
1
● Bit coding of key-operated switch
State
S1
S0
Key position
Position 0
0
0
In middle position
Position I
0
1
Turned in clockwise direction up to stop
Position II
1
0
Turned counter-clockwise up to stop
● Bit coding of illuminated pushbuttons