Detailed descriptions
16.6 Communications processor CP 1616 onboard
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
257
You can find additional, detailed information about the individual loader variants in the
integrated help.
Note
When loading the firmware or commissioning the module, be aware that the CP 1616
onboard takes five MAC addresses (always in direct sequence). The first two are shown in
the BIOS.
Figure 16-21 Advanced menu Peripheral Configuration
Example
The lower MAC address at "Profinet" is provided for Layer 2 communication, while the
second one is used for Ethernet/PROFINET communication.