Appendix
D
Setting Up Network Communications
D-4
SIMATIC HawkEye™ 1600T Smart Camera Guide
Rev. 1E, Nov 2007
SIMATIC HawkEye™ Boot Parameters
The SIMATIC HawkEye™ 1600T Smart Camera stores network and other
parameters in Non-Volatile memory. You can edit these by connecting a Serial
cable to the camera and HyperTerminal. The communication parameters must be
set to 115200-No Parity-8-1-No Flow Control.
Changing Network Parameters
To change network parameters:
1.
Start a HyperTerminal session with the communication parameters set to
115200-No Parity-8-1-No Flow Control.
2.
While you hold down the Escape key, cycle power on the SIMATIC
HawkEye™ 1600T Smart Camera. Information similar to the following is
displayed:
Siemens HawkEye Smart Camera
400MHz 16MB Flash 64MB RAM
-----------------------------
Name: HawkEyeE1000E
Static IP: 161.218.121.183
Network Mask: 255.255.255.0
Gateway: 0.0.0.0
DHCP: 1
MAC Address: 00:60:33:e1:12:34
1. Modify User Parameters
2. Reset User Account
3. Exit to Application
>>
3.
Type
1
to begin stepping through network parameters.
4.
For each parameter that is displayed, simply type in new information (to
change the parameter), or press the Return key to display the next parameter.
Eventually, you’ll see the message “Save parameters to flash? [y/n] -
5.
Type y and press the Return key. You’re finished changing network
parameters.
Содержание SIMATIC HawkEye 1600T Series
Страница 1: ...SIMATIC HawkEye 1600T Smart Camera Guide EM 40247 1E Rev 1E Nov 2007 ...
Страница 4: ......
Страница 8: ...Contents viii SIMATIC HawkEye 1600T Smart Camera Guide Rev 1E Nov 2007 ...
Страница 42: ...Chapter 3 Optics Lighting 3 4 SIMATIC HawkEye 1600T Smart Camera Guide Rev 1E Nov 2007 ...
Страница 64: ...Appendix C Specifications C 8 SIMATIC HawkEye 1600T Smart Camera Guide Rev 1E Nov 2007 ...
Страница 78: ...Appendix E Updating Firmware on 1600T Cameras E 10 SIMATIC HawkEye 1600T Smart Camera Guide Rev 1E Nov 2007 ...