Technical Specifications
B-2
SIMATIC Field PG P4 Manual
A5E00180080-04
General
Dimensions (w x h x d)
328 x 294 x 52 mm
Weight
approx. 4 kg
Line voltage external power supply
100 VAC to 240 VAC (+ 10% / – 15%), sinusoidal
Line voltage frequency
50 / 60 Hz (47 to 63 Hz)
Brief voltage interruption acc. to Namur
> 20 ms at 93 V
(AC power supply)
(max. 10 times per hour; min. recovery time 1 s)
Max. power consumption
Output DC voltage (external power supply)
Output DC current (external power supply)
Output DC power (external power supply)
Standby power ( battery operation)
Lithium Ion rechargeable battery (9 cells)
with charge-status monitoring
90 W
18.5 V
max. 4.3 A
max. 80 W
typ 1.5 W
approx. 6 Ah, 11.1 V with thermostatic switch and multifuse,
recyclable, chargeable up to 40
°
C (108
°
F), high number of
charge cycles under severe conditions, low self-discharge
rate
Degree of protection
IP30 (covers closed)
Quality assurance
ISO 9001
Safety
Requirements
VDE 0805 ^ EN 60950 and IEC 60950
Protection class I to IEC 60536
Protective separation between supply and secondary circuit
(via external power supply)
Noise emission
<45 dB(A) to DIN 45635
Electromagnetic compatibility (EMC)
Emitted interference
limit value class B to EN 55022, EN 6100–3–2,
Line-fed interference on AC supply lines
"
2 kV (IEC 61000-4-4; burst)
"
1 kV (IEC 61000-4-5;
m
s pulse/line to line)
"
2 kV (IEC 61000-4-5;
m
s pulse/line to ground)
Noise immunity on signal lines
"
2 kV (IEC 61000-4-4; burst; length >3 m)
"
2 kV (IEC 61000-4-5;
m
s pulse/line to ground;
length > 20 m)
Noise immunity to discharges of static
electricity
"
4kV, Contact discharge (IEC 61000-4-2; ESD)
"
8kV, Air discharge (IEC 61000-4-2; ESD)
Immunity to RF interference
10 V/m, with 80% amplitude modulation at 1 kHz,
9 kHz - 80 MHz (to IEC 61000-4-6)
10 V/m with 80% amplitude modulation at 1 kHz,
80 kHz - 1GHz (to IEC 61000-4-3)
10 V/m, pulse modulated 50% duty cycle, 900MHz and
1,89 GHz (to IEC 61000-4-3)
Magnetic field
30 A/m, 50Hz (to IEC 61000-4-8)
Содержание SIMATIC Field PG P4
Страница 8: ...Preface viii SIMATIC Field PG P4 Manual A5E00180080 04 ...
Страница 12: ...Contents xii SIMATIC Field PG P4 Manual A5E00180080 04 ...
Страница 18: ...Important Notes 1 6 SIMATIC Field PG P4 Manual A5E00180080 04 ...
Страница 92: ...Error Diagnostics 6 2 SIMATIC Field PG P4 Manual A5E00180080 04 ...
Страница 126: ...Technical Specifications B 6 SIMATIC Field PG P4 Manual A5E00180080 04 ...