Input/output modules
Hardware - SIMADYN D
5-21
Edition 12.2004
5
IT41
X6
Encoder with
tracks displaced
through 90º
Encoder with
forwards/
reverse
tracks
SU 10
at cable
end
B
Connector
designation
when
configuring
42 Encoder
ground
1
26 Encoder
ground
2
10 Monitoring
input,
encoder 1
3
43 Monitoring
input,
encoder 2
4
27 Monitoring
input,
encoder 3
5
11 Monitoring
input,
encoder 4
6
44
Alarm input 1
7
28
Alarm input 2
8
12
Alarm input 3
9
45
Alarm input 4
10
29
Alarm output 1
11
13
Alarm output 2
12
46
Alarm output 3
13
30
Alarm output 4
14
14
Alarm
ground
15
47
Ground (de-coupled)
Analog outputs
16
31
Ground (de-coupled)
Analog outputs
17
15
Analog output 1
18
X6E
48 Ground
19
32
Analog output 2
20
X6F
16 Ground
21
49
Analog output 3
22
X6G
33 Ground
23
17
Analog output 4
24
X6H
50 Ground
25
Table 5-16 Pin assignment IT41, connector X6 and terminal assignment SU10 at SC49,
end B
SU10 terminal
assignment at
SC49, end B