12.
Once the controller has detected the door "OPEN" and "CLOSED" end positions, the
subsequent opening and closing movements proceed at normal speed once again.
Note
Door movements in the "OPEN" and "CLOSE" directions can also be actuated with the
learn run button S501.
13.
The door travel values can be matched to the individual door for specific applications.
This requires the Service Tool to be connected.
A PC, on which the Software Kit operating program has been started, can also be
connected via the USB adapter, which is available as a special accessory. Its operation is
described in the Appendix to these instructions.
The following settings can be made:
Function
Adjustment range
Factory setting
Creep distance Open
0... 100 mm
25 mm
Cutter distance Open
0... 100 mm
30 mm
Creep distance Close
0... 100 mm
20 mm
Cutter distance Close
0... 100 mm
40 mm
Maximum speed Open
100... 500 mm/s
500 mm/s
Creep speed Open
30... 90 mm/s
40 mm/s
Cutter speed Open
30... 90 mm/s
60 mm/s
Initial speed Open
30... 90 mm/s
90 mm/s
Maximum speed Close
100... 500 mm/s
250 mm/s
Creep speed Close
30... 90 mm/s
60 mm/s
Cutter speed Close
30... 90 mm/s
40 mm/s
Initial speed Close
30... 90 mm/s
90 mm/s
Nudge speed Close
50... 250 mm/s
150 mm/s
Acceleration ramp OPEN
300... 850 mm/s
2
850 mm/s
2
Braking ramp OPEN
300... 850 mm/s
2
600 mm/s
2
Reversing ramp OPEN/CLOSE
300... 850 mm/s
2
850 mm/s
2
Acceleration ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Braking ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Reversing ramp CLOSE/OPEN
300... 850 mm/s
2
850 mm/s
2
Continuous torque (power) OPEN
0... 1.5 A
1 A
Continuous torque (power) CLOSE
0... 1.5 A
1 A
Cutter press-on torque
0... 5.0 A
2.5 A
Opening force static
70... 120 N
120 N
Closing force static
70... 120 N
110 N
Cutter force static Close
70... 120 N
110 N
Nudge force static Close
70... 120 N
110 N
Содержание SIDOOR AT12
Страница 2: ......
Страница 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Страница 10: ...Safety notes 2 1 General safety instructions Elevator door drive AT12 10 Manual 02 2012 A2B00086683A 04 ...
Страница 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Страница 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Страница 22: ...Mechanical installation and setting Elevator door drive AT12 22 Manual 02 2012 A2B00086683A 04 ...
Страница 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Страница 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Страница 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Страница 36: ...Technical data 12 3 Regulations and standards Elevator door drive AT12 36 Manual 02 2012 A2B00086683A 04 ...
Страница 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Страница 47: ......