Description of the device
3.1 Product overview
SCALANCE XR-500
20
Operating Instructions, 05/2017, A5E03275845-11
SCALANCE XR526-8C
For SCALANCE XR526-8C (24 VDC), the ambient temperature must not exceed 70 °C.
For SCALANCE XR526-
8C (240 VAC), the ambient temperature must not exceed 60 ℃.
SCALANCE XR526-8C
(24 VDC)
SCALANCE XR526-8C
(240 VAC)
Without pluggable transceiver of the types LH, LH+, ELH or
ELH200
0 °C to +70 °C
0 °C to +60 °C
With SFP transceivers (in SFP slots)
0 °C to +60 °C
0 °C to +60 °C
With SFP transceivers (in SFP+ slots)
0 °C to +60 °C
0 °C to +55 °C
With SFP+ transceivers (in
SFP+ slots)
6GK5 993-1AT00-8AA0
6GK5 993-1AU00-8AA0
6GK5 993-1AV00-8AA0
0 °C to +50 °C
0 °C to +50 °C
6GK5 993-1AT10-8AA0
6GK5 993-1AU10-8AA0
0 °C to +60 °C
0 °C to +55 °C
SCALANCE XR528-6M and SCALANCE XR552-12M
For SCALANCE XR528-6M and SCALANCE XR552-12M, the ambient temperature must not
exceed 60 °C.
SCALANCE XR528-6M
SCALANCE XR552-12M
Without filter pad and without SFP+ transceiver of the type LH 0 °C to +60 °C
0 °C to +60 °C
With filter pad and without SFP+ transceiver of the type LH
0 °C to +55 °C
0 °C to +55 °C
with filter pad and with SFP+ transceiver of the type LH
0 °C to +50 °C
0 °C to +50 °C
3.1.2
Accessories
Note
You will find detailed information on these products in the operating instructions on the
product DVD.
3.1.2.1
Accessories for the SCALANCE XR-500 product line
The following accessories are available for the SCALANCE XR-500 product line:
KEY-PLUG
Type
Article number
KEY-PLUG XR-500
6GK5 905-0PA00
Содержание SCALANCE XR-500
Страница 16: ...Safety notes 2 1 Security recommendations SCALANCE XR 500 16 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 36: ...Description of the device 3 5 Combo ports SCALANCE XR 500 36 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 72: ...Connecting 5 8 Functional ground SCALANCE XR 500 72 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 74: ...Uninstalling SCALANCE XR 500 74 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 94: ...Technical data 8 5 Switching properties SCALANCE XR 500 94 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 110: ...Certification 10 2 Mechanical stability in operation SCALANCE XR 500 110 Operating Instructions 05 2017 A5E03275845 11 ...