SCALANCE X-300M
Compact Operating Instructions, 10/2014, A5E02630801-06
41
Technical data
6
Note
Validity of the technical specifications
All the technical specifications described in this section that is not assigned to a specific
device variant, version or a media module, apply to all device variants/versions of the product
group.
6.1
Construction, installation and environmental conditions
Table 6- 1
Construction
Dimensions (W x H x D)
120 × 125 × 124 mm
Weight
1400 g
Degree of protection
IP20
Table 6- 2
Installation options
Installation options
•
DIN rail
1)
•
S7-300 standard rail
•
Wall
1)
Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35
mm DIN rail does not provide adequate support.
Table 6- 3
Permitted ambient conditions
Storage/transport temperature
-
40 °C to +85 ℃
Max. relative humidity in operation at 25 °C
< 95 % (no condensation)
Max. ambient temperature at operating altitude
2000 m or above:
-5 °C of the max. operating temperature
1)
3000 m or above:
-10 °C of the max. operating temperature
1)
1)
See table: "Operating temperature depending on the media modules used"