background image

 

Installation and Maintenance 

 

4.1 Installation 

Uninstalling

 

To remove SCALANCE X101-1AUI from the rail:

 

1.

 

First disconnect the TP cable and the AUI cables. Remove the terminal block for the 

power supply and the signaling contact. 

2.

 

Use a screwdriver to release the lower rail catch of the device and pull the lower part of 

the device away from the rail. 

 

 

Figure

 

4-2

 

Removing from a DIN rail (35 mm)

 

Industrial Ethernet Media Converters SCALANCE X-100 Series 
Commissioning Manual, 06/2006, A2B00051526A, Product Version 03 

4-3

 

Содержание SCALANCE X101-1AUI

Страница 1: ...Product Characteristics 3 Installation and Maintenance 4 Notes on the CE Mark 5 References 6 Dimension Drawings 7 SIMATIC NET SIMATIC NET Industrial Ethernet SCALANCE X101 1AUI Commissioning Manual 06 2006 A2B00051526A Product Version 03 ...

Страница 2: ...ified persons are defined as persons who are authorized to commission to earth and to tag circuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components f...

Страница 3: ...aling Contact 3 7 3 8 SCALANCE X101 1AUI Button 3 8 3 9 SCALANCE X101 1AUI LEDs 3 10 3 10 SCALANCE X101 1AUI Technical Specifications 3 11 4 Installation and Maintenance 4 1 4 1 Installation 4 1 4 1 1 Installation on a DIN Rail 4 2 4 1 2 Installation on a DIN Rail 4 4 4 1 3 Wall Mounting 4 5 4 2 Grounding 4 5 4 3 Assembling the IE FC Standard Cable 4 6 4 4 Assembling the AUI Cable 4 9 4 5 Maintena...

Страница 4: ...CALANCE X101 1AUI signaling contact 3 8 Figure 3 7 Connector pinout 3 8 Figure 4 1 Installation on a DIN rail 35 mm 4 2 Figure 4 2 Removing from a DIN rail 35 mm 4 3 Figure 4 3 Installation on a SIMATIC S7 300 DIN rail 4 4 Figure 4 4 IE FC RJ 45 plug 180 4 6 Figure 4 5 Inserting the IE FC RJ 45 plug 180 4 7 Figure 4 6 Unlatching the RJ 45 plug 4 8 Figure 4 7 Locking in open position 4 9 Figure 4 8...

Страница 5: ...tation The SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks manual contains additional information on other SIMATIC NET products that you can operate along with SCALANCE X101 1AUI in an Industrial Ethernet network Finding information To help you find the information you require more quickly the manual includes not only the table of contents but also the following sections in t...

Страница 6: ... ring since it does not support the redundancy function Note The requirements of EN61000 4 5 surge test on power supply lines are met only when a Blitzductor VT AD 24V type no 918 402 is used Manufacturer DEHN SÖHNE GmbH Co KG Hans Dehn Str 1 Postfach 1640 D 92306 Neumarkt Germany Warning When used under hazardous conditions zone 2 the SCALANCE X101 1AUI media converter must be installed in an enc...

Страница 7: ...ents The coupling shown here as an example illustrates the connection of an Industrial Ethernet switch to an existing 10Base5 segment Figure 2 1 Connection of a SCALANCE X108 to a 10Base5 segment via SCALANCE X101 1AUI Note SCALANCE X101 1AUI is a repeater This has to be considered when connecting and designing the network topology repeater rule Industrial Ethernet Media Converters SCALANCE X 100 ...

Страница 8: ......

Страница 9: ...ply with 12 V Signaling contact on site operation Diagnostics Web SNMP PROFINET C PLUG Ring redundancy with RM Standby redundancy IRT capability Fast learning Table 3 2 Overview of the possible attachments Characteristics Device type X101 1AUI TP RJ45 1 Attachment Unit Interface AUI for connecting a Medium Attachment Unit MAU 1 Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioni...

Страница 10: ...ecking 1 Make sure that the package is complete 2 Check all parts for transport damage Warning Do not use any parts that show evidence of damage Warning If the SCALANCE X101 1AUI device is operated in ambient temperatures between 55 C 60 C the temperature of the device housing may be higher than 70 C The subject unit must be located in a Restricted Access Location where access can only be gained b...

Страница 11: ...stics Possible Attachments SCALANCE X101 1AUI features an RJ 45 jack and a 15 pin SUB D socket for the connection to AUI transceivers MAU Medium Attachment Unit Figure 3 1 SCALANCE X101 1AUI Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 3 3 ...

Страница 12: ...45 jack Notice TP cords or TP XP cords with a maximum length of 10 m can be connected to the RJ 45 TP port Depending on the cable type a total cable length of up to 100 m is permitted between two devices with the IE FC cables and IE FC RJ 45 plug 180 Note The transmission mode of Scalance X101 1AUI is set to 10 Mbps half duplex Devices not supporting autonegotiation must be set to 10 Mbps half dup...

Страница 13: ...E X101 1AUI AUI Interface Transmission Rate The transmission rate is 10 Mbps Transmission Mode The AUI transmission mode is specified in the IEEE 802 3 standard Since half duplex mode and the transmission rate of 10Mbps are specified autonegotiation cannot be selected on the TP port Transmission Medium AUI cable drop cable EFB Ethernet transceiver cable Range The maximum transmission range segment...

Страница 14: ...n 14 Ground M GND Pin 13 Voltage Plus 12V Pin 12 DIN Data In Pin 11 Ground M GND Pin 10 DON Data Out Pin 9 CIN Control In Pin 8 Ground M GND Pin 7 NC Pin 6 Voltage Neg 12V Pin 5 DIP Data In Pin 4 Ground M GND Pin 3 DOP Data Out Pin 2 CIP Control In Pin 1 Ground M GND Industrial Ethernet Media Converters SCALANCE X 100 Series 3 6 Commissioning Manual 06 2006 A2B00051526A Product Version 03 ...

Страница 15: ...1 ground Pin 1 M2 ground Pin 2 L2 18 32V DC Warning The SCALANCE X101 1AUI device is designed for operation with safety extra low voltage This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals The power supply unit to supply SCALANCE X101 1AUI must comply with NEC Class 2 voltage range 18 32 V current requirement 470...

Страница 16: ... status by the button When turning off the device the signaling contact is always activated open 3 8 SCALANCE X101 1AUI Button What is the function of the button Using the button you can display and modify the set fault mask After continuously pressing the button the currently valid fault mask is displayed for approximately 3 seconds The LED of the monitored port flashes at a frequency of 5 Hz Kee...

Страница 17: ...tored port P1 or of one of the monitored power supplies is indicated by the illuminated red error LED The signaling contact is opened simultaneously Note The factory default is no port monitoring of port P1 but monitoring of the power supply L1 M1 If necessary error LED and signaling contact have to be cleared by pressing the button for an appropriate period or the feeding point has to be changed ...

Страница 18: ... not connected or L1 and L2 14 V Comment If the green LED is not lit no other signal LED is lit Port status indicator green yellow LEDs The status of the ports is indicated by 2 LEDs Status Meaning Port 1 LED lit green TP link exists no data reception Port 1 LED lit yellow TP link exists data received on TP port Port 2 LED lit yellow Bidirectional data communication on AUI port P2 Port 1 LED flash...

Страница 19: ...ELV Power loss at DC 24 V typ 3 W Current consumption at rated voltage typ at 2 1 W on 12V AUI output at 6 0 W on 12V AUI output 160 mA 350 mA Overvoltage protection at input PTC resettable fuse 1 0 A Max permitted power consumption of the load at the 12V AUI output MAU 6 W 500 mA 12V Permitted Cable Lengths Network span parameter TP cable length 0 100 m 0 85 m IE FC TP standard cable with IE FC R...

Страница 20: ...us CSA C22 2 No 60950 c Ul us for hazardous locations 1 UL 1604 UL 2279Pt 15 CL 1 Div 2 GP A B C D T CL 1 Zone 2 GP IIC T CL 1 Zone2 AEx nC IIC T FM 1 FM 3611 CL 1 Div 2 GP A B C D T CL 1 Zone 2 GP IIC T Ta C Tick AS NZS 2064 Class A CE EN 61000 6 2 EN 61000 6 4 replaces EN 50081 2 ATEX Zone 2 1 EN600079 15 II 3 G EEx nA II T KEMA 06 ATEX 0021 X MTBF MTBF 136years Construction Dimensions W x H x D...

Страница 21: ...TP trailing cable GP 6XV1870 2D IE FC TP flexible cable GP 6XV1870 2B IE FC RJ 45 plug 180 pack of 1 6GK1 901 1BB10 2AA0 IE FC RJ 45 plug 180 pack of 10 6GK1 901 1BB10 2AB0 IE FC RJ 45 plug 180 pack of 50 6GK1 901 1BB10 2AE0 Note When a frame passes through the SCALANCE X101 1AUI media converter it is typically delayed by approx 40 µs by the Cut Through function of the internal switch At a network...

Страница 22: ......

Страница 23: ...avoids an undesired temperature rise of the device and prevents premature ageing of device and cabling Warning If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken If the equipment is operated in an air ambient of 50 C 60 C only use cables with admitted maximum operating temperature of at least 80 C Warning Provisions ...

Страница 24: ...then push in the lower part of the device against the rail until it clips into place 2 Install the electrical connecting cables for the power supply and the terminal block for the signaling contact 3 Plug the terminal blocks in the corresponding sockets on the device Figure 4 1 Installation on a DIN rail 35 mm Industrial Ethernet Media Converters SCALANCE X 100 Series 4 2 Commissioning Manual 06 2...

Страница 25: ...ove the terminal block for the power supply and the signaling contact 2 Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail Figure 4 2 Removing from a DIN rail 35 mm Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 4 3 ...

Страница 26: ...ectors for the signaling contact 5 Plug the terminal blocks in the corresponding sockets on the device Figure 4 3 Installation on a SIMATIC S7 300 DIN rail Uninstalling To remove the media converters of the SCALANCE X 100 series from the SIMATIC S7 300 DIN rail 1 First remove all connected cables 2 Unscrew the screw fittings at the lower part of the standard rails and subsequently pull the device ...

Страница 27: ...porting at least four times the weight of the device 4 2 Grounding Installation on a DIN Rail The device is grounded over the DIN rail S7 DIN Rail The device is grounded over its rear panel and the neck collar screw Wall mounting The device is grounded by the securing screw in the unpainted hole Please note that SCALANCE X101 1AUI must be grounded over one securing screw with minimum resistance If...

Страница 28: ...bly please refer to the instructions that ship with the IE FC RJ 45 plug 180 The robust connectors of the nodes are designed for industry and are PROFINET compliant Due to the locking mechanism on the casing they provide additional strain and torsion relief Figure 4 4 IE FC RJ 45 plug 180 Industrial Ethernet Media Converters SCALANCE X 100 Series 4 6 Commissioning Manual 06 2006 A2B00051526A Produ...

Страница 29: ...into place Figure 4 5 Inserting the IE FC RJ 45 plug 180 Due to the closing shape and the latching with the PROFINET compliant connector IE FC RJ 45 plug 180 the sleeve at the TP port of SCALANCE X101 1AUI ensures a robust industry standard node connection which provides additional strain and torsion relief of the twisted pair port Industrial Ethernet Media Converters SCALANCE X 100 Series Commiss...

Страница 30: ...to remove the plug Figure 4 6 Unlatching the RJ 45 plug If for lack of space a manual unlatching is not possible you can also unlatch the plug with a 2 5 mm screwdriver Subsequently you can remove the IE FC RJ 45 plug 180 from the twisted pair port Industrial Ethernet Media Converters SCALANCE X 100 Series 4 8 Commissioning Manual 06 2006 A2B00051526A Product Version 03 ...

Страница 31: ... as follows The 15 pin sub D socket has a locking To loosen the connector press the locking down and press it up to close it Figure 4 7 Locking in open position Figure 4 8 Locking or unlocking the SUB D connector Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 4 9 ...

Страница 32: ... all LEDs are off despite correctly applied power supply the device should be disconnected from the power supply for approx 30 minutes before it can be turned on again If a fault develops please send the device to your SIEMENS service center for repair Repairs on site are not possible Industrial Ethernet Media Converters SCALANCE X 100 Series 4 10 Commissioning Manual 06 2006 A2B00051526A Product ...

Страница 33: ...munity Industrial operation EN 61000 6 4 2001 replaces EN 50082 2 EN 61000 6 2 2001 replaces EN 50081 2 Installation Guidelines The products meet the requirements if you keep to the installation instructions and safety related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks 1 manual when installing and operating the device Industrial Ether...

Страница 34: ...ach 4848 D 90327 Nürnberg Notes for Manufacturers of Machines The products are not machines in the sense of the EC Machinery Directive There is therefore no declaration of conformity for the EU directive on machines 89 392 EEC for these products If the products are part of the equipment of a machine they must be included in the procedure for the declaration of conformity by the manufacturer of the...

Страница 35: ...works Order numbers 6GK1970 1BA10 0AA0 German 6GK1970 1BA10 0AA1 English 6GK1970 1BA10 0AA2 French 6GK1970 1BA10 0AA4 Italian 2 PROFINET Installation Guide can be ordered from the PROFIBUS User Organization PNO Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 6 1 ...

Страница 36: ......

Страница 37: ...Dimension Drawings 7 7 1 Dimension Drawing Figure 7 1 Dimension drawing Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 7 1 ...

Страница 38: ...imension Drawings 7 1 Dimension Drawing Figure 7 2 SCALANCE X101 1AUI side view Industrial Ethernet Media Converters SCALANCE X 100 Series 7 2 Commissioning Manual 06 2006 A2B00051526A Product Version 03 ...

Страница 39: ...on Method standardized according to IEEE 802 3 with which transmission parameters e g 10 100 Mbps full half duplex between devices are automatically negotiated C PLUG The C PLUG configuration plug is a swap medium for backing up the configuration data If the device is replaced the configuration can be applied by exchanging the C PLUG CRC Cyclic Redundancy Check A checksum used in transmission prot...

Страница 40: ...r is also 125 µm The actual transmission of the information takes place in the core of the fiber Multicast A frame with a multicast address is received by all recipients which are ready for receiving this address Multimode In multimode transmission the pulse is transferred using many modes waves which travel along curved paths or which are reflected within the core Attenuation is mainly caused by ...

Страница 41: ... One switch in the ring must be configured as redundancy manager This switch sends test frames via the ring ports that are forwarded by all ring ports of other switches in the ring This ensures that the ring does not have any interruptions Segment In the Ethernet bus system the transceivers connected over the bus cable along with the nodes connected over patch cables form a segment Several such se...

Страница 42: ......

Страница 43: ...3 5 N Network topology Coupling of network segments 2 1 P Port status indicator green yellow LEDs 3 10 Possible attachments 3 3 Power indicator green LED 3 10 Power supply 3 7 S Signaling contact 3 8 T Transparent link display green LED 3 10 U UL mark 1 2 Industrial Ethernet Media Converters SCALANCE X 100 Series Commissioning Manual 06 2006 A2B00051526A Product Version 03 Index 1 ...

Отзывы: