Product Characteristics
3.10 SCALANCE X101-1AUI Technical Specifications
3.10
SCALANCE X101-1AUI Technical Specifications
Technical Specifications of SCALANCE X101-1AUI
Ports
Attachment of DTEs or network components over
twisted pair
1xRJ-45 socket with MDI-X pinning 10 Mbps
(half duplex according to 10BaseT)
Connection of further network components via
AUI cable (drop cable)
1x 15-pin SUB-D socket
(10 Mbps, half duplex)
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Electrical Data
Power supply
2 x DC 24 V
(DC 18 - 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.)
3 W
Current consumption at rated voltage (typ.)
-
at 2.1
W on 12V AUI output
-
at 6.0
W on 12V AUI output
160 mA
350 mA
Overvoltage protection at input
PTC resettable fuse (1.0 A)
Max. permitted power consumption of the load at
the 12V AUI output (MAU)
6 W (500 mA / 12V)
Permitted Cable Lengths
Network span parameter/TP cable length
0
–
100 m
0 –85 m
IE FC TP standard cable with
IE FC RJ-45 plug 180
or
IE FC outlet RJ-45 with IE FC TP standard cable
(0 - 90 m) + 10 m TP cord
IE FC TP marine/trailing/flexible with
IE FC RJ-45 plug 180
or
IE FC TP marine/trailing/flexible (0
–
75 m) +
10 m TP cord over IE FC outlet RJ-45
Network span parameter/AUI cable length
0 - 50 m
AUI cable (drop cable)
Industrial Ethernet Media Converters SCALANCE X-100 Series
Commissioning Manual, 06/2006, A2B00051526A, Product Version 03
3-11