Product Characteristics
4.2 SCALANCE X101-1
Permitted Environmental Conditions / EMC
Operating temperature
-10°C to +60°C
Storage/transport temperature
-40°C to +80°C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
RF interference level
EN 61000-6-3
Noise immunity
EN 61000-6-2
Degree of protection
IP30
Approvals
UL 60950
c-UL-us
CSA C22.2 No. 60950
c-Ul-us for hazardous locations
UL 1604, UL 2279Pt.15
CL. 1, Div. 2 GP. A.B.C.D T..
CL. 1, Zone 2, GP. IIC, T..
CL. 1, Zone2, AEx nC IIC T..
FM
3
FM 3611
CL. 1, Div. 2 GP. A.B.C.D T..
CL. 1, Zone 2, GP. IIC, T..
Ta: ..
C-Tick
AS/NZS 2064 (Class A).
CE
EN 61000-6-2, EN 61000-6-4
ATEX Zone 2
3
EN60079-15:2005
EN60079-0:2006
II 3 G Ex nA II T..
KEMA 08 ATEX 0003 X
MTBF
MTBF
134 years
Construction
Dimensions (W x H x D) in mm
40 x 125 x 124
Weight in g
550
Installation options
DIN rail
S7-300 DIN rail
Wall mounting
3
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
Industrial Ethernet Media Converters SCALANCE X-100 Series
4-12
Commissioning Manual, 07/2008, A2B00051521A