Technical specifications
SCALANCE X-000
Operating Instructions, 09/2016, C79000-G8976-C344-02
37
Note
The number of connected SCALANCE X Industrial Ethernet Switches influences the frame
propagation time.
When a frame passes through the SCALANCE X005, it is delayed by the store and forward
function of the switch:
•
with a 64 byte frame length by approx. 10 µs (at 100 Mbps)
•
with a 1500 byte frame length by approx. 130 µs (at 100 Mbps)
This means that the more SCALANCE X005 the frame passes through, the longer the frame
delay.