Connecting up
5.2 Wiring rules
SCALANCE X-000
Operating Instructions, 09/2016, C79000-G8976-C344-02
25
5.2
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
Screw/spring-loaded termi-
nals
connectable cable cross sec-
tions for flexible cables ...
without wire end ferrule
0.25 - 2.5 mm
2
AWG: 24 - 13
with wire end ferrule with plastic fer-
rule**
0.25 - 2.5 mm
2
AWG: 24 - 13
with wire end ferrule without plastic
ferrule**
0.25 - 2.5 mm
2
AWG: 24 - 13
with TWIN wire end ferrule**
0.5 - 1 mm
2
AWG: 20 - 17
Stripped length of the cable
8 - 10 mm
Wire end ferrule according to DIN 46228 with plastic ferrule**
8 - 10 mm
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped
crimp cross sections.
Crimp shapes with wave-shaped profile are unsuitable.
Содержание SCALANCE X-000
Страница 4: ...Table of contents SCALANCE X 000 4 Operating Instructions 09 2016 C79000 G8976 C344 02 ...
Страница 10: ...Network topologies SCALANCE X 000 10 Operating Instructions 09 2016 C79000 G8976 C344 02 ...
Страница 30: ...Connecting up 5 5 IE FC RJ 45 Plug 180 SCALANCE X 000 30 Operating Instructions 09 2016 C79000 G8976 C344 02 ...
Страница 32: ...Maintenance and troubleshooting SCALANCE X 000 32 Operating Instructions 09 2016 C79000 G8976 C344 02 ...
Страница 38: ...Technical specifications SCALANCE X 000 38 Operating Instructions 09 2016 C79000 G8976 C344 02 ...
Страница 44: ...Approvals SCALANCE X 000 44 Operating Instructions 09 2016 C79000 G8976 C344 02 ...