Configuration
3.3 Reset and Defaults
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
74
Configuration Manual, 11/2014, C79000-G8976-C351-03
3.3
Reset and Defaults
This section describes commands for restarting the device and for restoring the original
configuration.
3.3.1
restart
Description
With this command, you restart the device.
Select one of the following configuration settings:
●
Device restart with the current configuration
●
Device restart with the factory configuration settings with the exception of the following
parameters:
–
IP addresses
–
Subnet mask
–
IP address of the default gateway
–
DHCP client ID
–
DHCP
–
System name
–
System location
–
System contact
–
User names and passwords
–
Mode of the device
●
Device restart with the factory configuration settings.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#