Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
429
Parameter
Description
trap
Client that sends the SNMP traps
faults
Error LED lights up. The setting is possible only for a cold or warm restart.
digital-out
Controls the digital output or signals the status change with the "DO" LED.
vpn-tunnel
Controls the VPN connection (establishment/termination).
all
All clients at once
Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the
show events config
command.
You configure which of the various message types of the device will be stored or forwarded
with the
event config
command.
10.1.10.6
link
Description
With this command, you configure and enable the monitoring of the physical network
connections for cable breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
link {up|down}
The parameters have the following meaning:
Parameters
Description
Range of values
up
Only the establishment of a connection is signaled
-
down
Only a break on a connection is signaled
-
Содержание SCALANCE S615
Страница 6: ...Preface SCALANCE S615 Command Line Interface 6 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 130: ...System time 4 2 NTP client SCALANCE S615 Command Line Interface 130 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 138: ...System time 4 3 SNTP client SCALANCE S615 Command Line Interface 138 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 170: ...Network structures 5 1 VLAN SCALANCE S615 Command Line Interface 170 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 302: ...Layer 3 functions 8 1 NAT SCALANCE S615 Command Line Interface 302 Configuration Manual 06 2015 C79000 G8976 C406 02 ...