![Siemens SCALANCE S615 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351024.webp)
Description
1.4 Symbols of the CLI commands
SCALANCE S615 Command Line Interface
24
Configuration Manual, 06/2015, C79000-G8976-C406-02
1.4
Symbols of the CLI commands
Symbols for representing CLI commands
When setting parameters for CLI commands, the following characters are used:
Charac-
ter
Meaning
< ... >
mandatory parameter
Instead of the expression in parenthesis, enter a value.
[ ... ]
optional parameter
Instead of the expression in parenthesis, you can enter a
value.
( ... )
Value or range of values Instead of the expression in parenthesis, enter a value.
( ... - ... ) Range of values
Enter a value from this range.
{ ... }
Selection list
Select one more elements from the list.
{ ... | ... } exclusive selection
Select exactly one element from this list.
These characters are used in combinations to describe mandatory and optional entries.
There is a general description of some of these combinations below:
Character combinations
Meaning
< Parameter >
Instead of the expression in parentheses<>, enter a permitted
value.
< < Unit (a - b) >
Instead of the expression in parentheses <>, enter a value from
the range "a" to "b".
The unit to be used is specified before the brackets () and is
also replaced by the entry.
[<Parameter 1 >< Parameter 2 >]
The parameter pair is optional.
If you use the parameter assignment, you need to enter a per-
mitted value to replace both expressions in parenthesis <>.
[ [ Keyword < Unit (a - b)>]
The parameter assignment is optional.
If you use the keyword, you need to enter a value from the
range "a" to "b" to replace the expression in parenthesis <>.
[keyword { A | B | C }]
The parameter assignment is optional.
If you use the keyword, you need to specify exactly one of the
values "A", "B" or "C".
Keyword [A] [B] [C]
After the keyword, enter no or several of the values "A", "B" or
"C".
Содержание SCALANCE S615
Страница 6: ...Preface SCALANCE S615 Command Line Interface 6 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 130: ...System time 4 2 NTP client SCALANCE S615 Command Line Interface 130 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 138: ...System time 4 3 SNTP client SCALANCE S615 Command Line Interface 138 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 170: ...Network structures 5 1 VLAN SCALANCE S615 Command Line Interface 170 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 302: ...Layer 3 functions 8 1 NAT SCALANCE S615 Command Line Interface 302 Configuration Manual 06 2015 C79000 G8976 C406 02 ...