Network structures
5.1 VLAN
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
147
5.1.2.3
no interface range
Description
With this command, you remove the interfaces or interfaces of VLANs from the interface
range or break it up if you first remove all previously added interfaces.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no interface range vlan <vlan-id(1-4094)> - <vlan-id(2-4094)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN
1 ... 4094
vlan-id
Number of the addressed VLAN
2 ... 4094
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
If you address several VLANs, you must insert a blank before and after the hyphen, for
example
no interface range vlan 5 - 10
.
Result
The VLANs have been removed from the specified interface area.
Further notes
With the
interface range
command, you can put several interfaces or VLANs together to be
able to configure them together.
Содержание SCALANCE S615
Страница 6: ...Preface SCALANCE S615 Command Line Interface 6 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 130: ...System time 4 2 NTP client SCALANCE S615 Command Line Interface 130 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 138: ...System time 4 3 SNTP client SCALANCE S615 Command Line Interface 138 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 170: ...Network structures 5 1 VLAN SCALANCE S615 Command Line Interface 170 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 302: ...Layer 3 functions 8 1 NAT SCALANCE S615 Command Line Interface 302 Configuration Manual 06 2015 C79000 G8976 C406 02 ...